Zobrazeno 1 - 10
of 64
pro vyhledávání: '"Jules, Cadorette"'
Autor:
N. Viscogliosi, Jean-François Beaudoin, Rejean Fontaine, J.-D. Leroux, Catherine M. Pepin, Louis Arpin, Christian Thibaudeau, Maxime Toussaint, Jonathan Bouchard, Konin Koua, Roger Lecomte, Maxime Paille, Caroline Paulin, Emilie Gaudin, Jules Cadorette
Publikováno v:
Phys Med Biol
The LabPET II is a new positron emission tomography technology platform designed to achieve submillimetric spatial resolution imaging using fully pixelated avalanche photodiodes-based detectors and highly integrated parallel front-end processing elec
Autor:
Jean-François Beaudoin, Jules Cadorette, Louis Arpin, Jonathan Charest, Charles-Antoine Brunet, Melanie Bergeron, Roger Lecomte, Rejean Fontaine
Publikováno v:
IEEE Transactions on Nuclear Science. 63:2550-2557
Stable system performance is mandatory to warrant the accuracy and reliability of biological results relying on small animal positron emission tomography (PET) imaging studies. This simple requirement sets the ground for imposing routine quality cont
Autor:
Catherine M. Pepin, Pierre Deschamps, Henri Dautet, Christian Thibaudeau, Marc-Andre Tetrault, Jules Cadorette, Maelanie Bergeron, Murray Davies, Francis Loignon-Houle, Roger Lecomte, Rejean Fontaine, Julien Clerk-Lamalice
Publikováno v:
IEEE Transactions on Nuclear Science. 62:756-765
Computed tomography (CT) is currently the standard modality to provide anatomical reference for positron emission tomography (PET) in molecular imaging applications. Since both PET and CT rely on detecting radiation to generate images, using the same
Autor:
Rejean Fontaine, Roger Lecomte, Jules Cadorette, Catherine M. Pepin, Francis Loignon-Houle, Melanie Bergeron
Publikováno v:
IEEE Transactions on Nuclear Science. 62:36-41
The scintillator is one of the key building blocks that critically determine the physical performance of PET detectors. The quest for scintillation crystals with improved characteristics has been crucial in designing scanners with superior imaging pe
Autor:
Roger Lecomte, Marc-Andre Tetrault, Jules Cadorette, Charles-Antoine Brunet, J.-B. Michaud, J.-D. Leroux, Rejean Fontaine, Jean-François Beaudoin
Publikováno v:
IEEE Transactions on Nuclear Science. 62:82-94
Scanner sensitivity is often critical in high-resolution Positron Emission Tomography (PET) dedicated to molecular imaging. In neighboring pixelated detectors with individual readout, sensitivity decreases because of multiple coincidences produced by
Autor:
Roger Lecomte, N. Viscogliosi, Henri Dautet, P. Berard, R. Fontaine, Melanie Bergeron, Marc-Andre Tetrault, Catherine M. Pepin, Jules Cadorette, Murray Davies
Publikováno v:
Medical physics. 35(7Part3)
Visualization and quantification of biological processes in mice, the preferred animal model in most preclinical studies, require the best possible spatial resolution in positron emission tomography (PET). A new 64-channel avalanche photodiode (APD)
Autor:
Jean-François Beaudoin, Jules Cadorette, Jonathan Charest, Charles-Antoine Brunet, Roger Lecomte, Rejean Fontaine
Publikováno v:
IEEE Transactions on Nuclear Science. 61:2494-2502
Avalanche photodiode (APD) based positron emission tomography (PET) scanners show enhanced imaging capabilities in terms of spatial resolution and contrast due to the one to one coupling and size of individual crystal-APD detectors. However, to ensur
Autor:
Mohamed Walid Ben attouch, Caroline Paulin, Pascale Maille, Jean-Francois Pratte, Roger Lecomte, Jean-Christophe Lavoie, Adrien Burghgraeve, Heythem Bouziri, Marc-Andre Tetrault, Sylvain Panier, Jules Cadorette, Mouadh Abidi, Konin Koua, Louis Arpin, Larissa Njejimana, Rejean Fontaine
Publikováno v:
IEEE Transactions on Nuclear Science. 60:3633-3638
To achieve submillimetric spatial resolution, a new detection block has been designed for the LabPET II, a small animal PET scanner being developed at Universite de Sherbrooke. Each detection block consists of 2 arrays of 4×8 avalanche photodiodes (
Autor:
Marc-Andre Tetrault, Jules Cadorette, Catherine M. Pepin, Rejean Fontaine, Murray Davies, P. Berard, Roger Lecomte, Pierre Deschamps, Melanie Bergeron, N. Viscogliosi, Henri Dautet
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 610:20-23
Visualization and quantification of biological processes by molecular imaging in small animals such as rats and especially mice require the best possible spatial resolution in positron emission tomography (PET). A new avalanche photodiode (APD) detec
Autor:
F. Belanger, Louis Arpin, J. Riendeau, N. Viscogliosi, P. Berard, Roger Lecomte, Marc-Andre Tetrault, Jules Cadorette, Martin Lepage, G. Robert, H. Semmaoui, Melanie Bergeron, F. Lemieux, Catherine M. Pepin, Rejean Fontaine, J.-B. Michaud
Publikováno v:
IEEE Transactions on Nuclear Science. 55:2546-2550
To address modern molecular imaging requirements, a digital positron emission tomography (PET) scanner for small animals has been developed at Universite de Sherbrooke. Based on individual readout of avalanche photodiodes (APD) coupled to LYSO/LGSO p