Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Jozef Vander Sloten"'
Autor:
Rui Farinha, Alberto Breda, James Porter, Alexandre Mottrie, Ben Van Cleynenbreugel, Jozef Vander Sloten, Angelo Mottaran, Anthony G. Gallagher
Publikováno v:
European Urology Focus. 9:388-395
Robot-assisted partial nephrectomy (RAPN) training usually takes place in vivo, and methods vary across countries/institutions. No common system exists to objectively assess trainee ability to perform RAPN at predetermined performance levels prior to
Autor:
Rui Farinha, Alberto Breda, James Porter, Alexandre Mottrie, Ben Cleynenbreugel, Jozef Vander Sloten, Angelo Mottaran, Anthony Gallagher
Publikováno v:
Journal of Robotic Surgery.
Background RAPN training usually takes place in-vivo and methods vary across countries/ institutions. No common system exists to objectively assess trainee capacity to perform RAPN at predetermined performance levels prior to in-vivo practice. The id
Autor:
Joke Duyck, Ignace Naert, Jozef Vander Sloten, Liesbet Geris, Katleen Vandamme, Hans Van Oosterwyck
Publikováno v:
Tissue Engineering Part A. 16:3353-3361
Despite a myriad of studies confirming the interaction between biology and mechanics, the exact nature of the main mechanical stimuli and their influence on the bone regeneration processes are still unclear. The hypothesis of this study was that the
Autor:
Jozef Vander Sloten, Frank Van Calenbergh, Paul Suetens, Joris Walraevens, Johan van Loon, Philippe Demaerel, Jan Goffin
Publikováno v:
Neurosurgery. 67:679-687
Background Many short- and intermediate-term radiological and clinical studies on cervical arthroplasty with the Bryan Cervical Disc have been published, providing, most of the time, satisfactory results. Objective To prospectively assess the interme
Publikováno v:
Journal of Spinal Disorders & Techniques. 23:372-376
Study design In a radiographic study, postoperative segmental alignment was compared between 2 cohorts of 20 consecutive patients operated with a Bryan Cervical Disc Prosthesis. In group 2, patients with severe preoperative kyphosis were excluded for
Autor:
Jean-Marie Aerts, Jozef Vander Sloten, Daniel Berckmans, Jan Goffin, Ignace Verpoest, Guido De Bruyne
Publikováno v:
International Journal of Industrial Ergonomics. 40:406-413
This research aims at quantifying transient spatial gradients in sweat production on a human head while cycling. Six test persons were studied. Each test lasted 30 min while a change in work rate was applied after 5 min (from 80 to 150 W for males an
Publikováno v:
Journal of Periodontology. 79:150-157
Critical factors for the establishment of osseointegration are the implant surface microtopography and the local mechanical environment. The present study evaluated the bone response around a turned (T) and a roughened (R) implant for either an unloa
Publikováno v:
European Journal of Oral Sciences. 115:21-29
Initial osteogenesis at the implant interface is, to a great extent, determined by the implant surface characteristics and the interfacial loading conditions. The present study investigated the effect of various degrees of relative movement on the ti
Autor:
Remy Van Audekercke, Bart Depreitere, Jozef Vander Sloten, Georges Van der Perre, Christiaan Plets, Jan Goffin, Carl Van Lierde
Publikováno v:
Journal of Neurosurgery. 104:950-956
Object Based on data from primate experiments it is known that rotational acceleration in the sagittal plane and in a forward direction is most likely to produce acute subdural hematomas due to bridging vein rupture. For protection against these lesi
Autor:
Rosy Eloy, Claire Delubac, Lothar H.O. Buth, Patrice Brenner, Jozef Vander Sloten, Siegfried Jaecques, Jan Schrooten, Jan Van Humbeeck, Christoph Schultheiss
Publikováno v:
Key Engineering Materials. :427-430