Advanced mathematical skills and relating factors of engineering applicants: a cross-sectional study
Higher education institutions assess applicants with entrance examinations as a way to identify and rank those applicants with adequate ability to proceed in their studies. Engineering students form a significant group of higher education students, b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b1e4f373d9a85b0bcd7fff20693347a9
https://hdl.handle.net/2117/383914
https://hdl.handle.net/2117/383914
Publikováno v:
Björkman, J, Baroudi, D, Latva, R, Tuomisaari, M & Kokkala, M 2002, ' Determination of dynamic model parameters of smoke detectors ', Fire Safety Journal, vol. 37, no. 4, pp. 395-407 . https://doi.org/10.1016/S0379-7112(01)00058-3
A simple model for the dynamic response of point-type smoke detectors is described. The model is based on two independent parameters: the characteristic length and the static response threshold. Experimentally determined values of the parameters for
Autor:
Esko Mikkola, Jouni Björkman
Publikováno v:
Fire and Materials. 25:185-192
The fire risk assessment model CRISP2 was applied to a 4-storey apartment building. The case building was an actual 4-storey timber-framed building. Partly predetermined design alternatives were used in sequential simulations. CRISP2 cannot take into
Publikováno v:
Björkman, J, Kokkala, M & Ahola, H 1992, ' Measurements of the characteristic lengths of smoke detectors ', Fire Technology, vol. 28, no. 2, pp. 99-106 . https://doi.org/10.1007/BF01857936
The dynamic performance of point-type smoke detectors is described by a simple model including two independent parameters, the static response threshold, and the characteristic length of the detector. An experimental system with constant rate of incr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c6165eb283ab03638ce21595c0fd0d67
https://cris.vtt.fi/en/publications/36dde54c-afc2-435f-bd97-dd983293043e
https://cris.vtt.fi/en/publications/36dde54c-afc2-435f-bd97-dd983293043e
Publikováno v:
Fire Technology. 28:108-109