Autor:
Joseph Z Su
Publikováno v:
Wood and Fiber Science. 50:102-109
This article provides an overview of the code requirements pertinent to large cross-laminated timber (CLT) buildings and the methods for meeting the requirements in Canada. Canadian building codes are objective-based. Compliance with the code is achi
Autor:
T.R. Hull, David Purser, Colin Moffatt, Anna A. Stec, M. Bijloos, J. A. Purser, Joseph Z. Su, Per Blomqvist
Publikováno v:
Fire Safety Journal. 55:22-34
The ISO/TS 19700 steady state tube furnace is designed to measure the yields of combustion products, and in particular toxic combustion products, under a range of different specified decomposition conditions occurring in full-scale compartment fires.
Publikováno v:
Fire Technology. 47:631-664
A full-scale experimental program was undertaken to study the impact of two basement fire scenarios on the structural integrity of unprotected floor assemblies above a basement and the tenability conditions in a test facility representing a typical t
Autor:
Joseph Z. Su, G. Crampton
Publikováno v:
Fire Technology. 45:97-115
North American smoke-alarm installation standards and manufacturer’s recommendations require that smoke alarms be installed not less than 100 mm from any adjoining wall if mounted on a flat ceiling, and not closer than 100 mm and not farther than 3
Autor:
Joseph Z. Su, Andrezza Kyunmi Kim
Publikováno v:
Fire Technology. 38:7-32
Handheld FM-200, FE-36, CF3I and Halotron I extinguishers with 2B:C, 5B:C and 10B:C ratings (or equivalent) were tested for extinguishing Class B heptane pool fires in small and large enclosures (45, 120 and 21000 m3). Test results showed that the Ha
Publikováno v:
Journal of Fire Protection Engineering. 11:164-193
This paper describes water mist fire suppression effectiveness under various ventilation conditions. The full-scale fire test series were conducted in an empty enclosure and in a simulated machiner...
Publikováno v:
Fire Technology. 35:336-361
We conducted a series of full-scale fire tests of a twin-fluid water mist system in an empty enclosure and in a simulated machinery space. During the tests, two water mist discharge modes, continuous and cycling, were used. We investigated the exting
Publikováno v:
Journal of Fire Protection Engineering. 8:45-63
This paper provides a review of total flooding gaseous agents as Halon 1301 substitutes. Agents are compared, based on published data, in terms of their environmental impact, toxicity, fire suppression performance, and acid gas production from small-
Autor:
Andrew K. Kim, Joseph Z. Su
Full-scale fire suppression testing of HFC-227ea and HCFC Blend A was conducted in a 121 m3 compartment. HFC-227ea was tested at 7.6 and 8.8%; HCFC Blend A was tested at 8.6, 9.3, 10, 12 and 14% (by volume). Information on discharge characteristics a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ab6e3bcb1ea1c6c6d37689d15da764fb
https://doi.org/10.1177/104239159901000201
https://doi.org/10.1177/104239159901000201
During full-scale fire suppression tests using HFC-227ea and HCFC Blend A, the Fourier transform infrared spectroscopic method was used to monitor the gas composition of the air in a 121 m 3 test compartment. These agents were observed to produce hal