Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Joseph M. Smolinski"'
Autor:
James D Tucker, George W Divine, William E Grever, Robert A Thomas, Michael C Joiner, Joseph M Smolinski, Gregory W Auner
Publikováno v:
PLoS ONE, Vol 8, Iss 12, p e83390 (2013)
Rapid and reliable methods for performing biological dosimetry are of paramount importance in the event of a large-scale nuclear event. Traditional dosimetry approaches lack the requisite rapid assessment capability, ease of use, portability and low
Externí odkaz:
https://doaj.org/article/3b5a78703de94533b104184f311d8063
Autor:
James D. Tucker, Michael C. Joiner, Marina V. Bakhmutsky, Robert A. Thomas, George Divine, Chantelle N. Chinkhota, Joseph M. Smolinski, William E. Grever, Gregory W. Auner
Publikováno v:
International Journal of Radiation Oncology*Biology*Physics. 88:933-939
Purpose Rapid and reliable methods for conducting biological dosimetry are a necessity in the event of a large-scale nuclear event. Conventional biodosimetry methods lack the speed, portability, ease of use, and low cost required for triaging numerou
Autor:
Robert A. Thomas, Andre Konski, Michael C. Joiner, James D. Tucker, George Divine, William E. Grever, Gregory W. Auner, Joseph M. Smolinski
Publikováno v:
Radiation Research. 177:209-219
In a large-scale nuclear incident, many thousands of people may be exposed to a wide range of radiation doses. Rapid biological dosimetry will be required on an individualized basis to estimate the exposures and to make treatment decisions. To amelio
Autor:
Gregory W. Auner, James D. Tucker, Robert A. Thomas, Chantelle N. Hughes-Chinkhota, Joseph M. Smolinski, Dayton M. Petibone, Malathi Banda
Publikováno v:
Sensors and Actuators B: Chemical. 155:437-445
Fabrication of microfluidic systems capable of extracting and isolating nucleic acids from biological samples and preparing them for downstream applications within the same device is of interest as on-chip sample preparation reduces the time and effo
Publikováno v:
Sensors and Actuators B: Chemical. 132:272-279
Performance of a conventional phase detector implemented using analog circuitry is affected by, among other factors, the parameter value drifting of the analog components with environment (e.g., temperature) and time (i.e., aging). It is also adverse
Effect of polymer–surfactant interactions on elongational viscosity and atomization of peo solutions
Publikováno v:
Journal of Non-Newtonian Fluid Mechanics. 138:1-6
The elongational viscosities of aqueous solutions of polyethylene oxide (PEO) containing either sodium dodecyl sulfate (SDS) or sodium dodecyl benzyl sulfonate (SDBS) are measured by an opposing jet elongational rheometer. The elongational viscositie
Autor:
Robert A. Thomas, Michael C. Joiner, Joseph M. Smolinski, James D. Tucker, George Divine, Gregory W. Auner, William E. Grever
Publikováno v:
PLoS ONE
PLoS ONE, Vol 8, Iss 12, p e83390 (2013)
PLoS ONE, Vol 8, Iss 12, p e83390 (2013)
Rapid and reliable methods for performing biological dosimetry are of paramount importance in the event of a large-scale nuclear event. Traditional dosimetry approaches lack the requisite rapid assessment capability, ease of use, portability and low
Publikováno v:
AIChE Journal. 42:1201-1212
Atomization experiments, motivated by the need to suppress misting of machining oils, were conducted on dilute solutions of polyisobutylene (PIB) in mineral oil using a coaxial air blast atomizer and an optical (Fraunhofer diffraction) particle sizer
Autor:
Michael C. Joiner, William E. Grever, Robert A. Thomas, George Divine, Gregory W. Auner, Joseph M. Smolinski, Andre Konski, James D. Tucker
Publikováno v:
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 101(1)
Background and purpose Systems are being developed to assess radiation exposure based on leukocyte mRNA levels obtained by finger-stick sampling. The goal is to provide accurate detection of dose exposures up to 10Gy for up to 1week following exposur
Publikováno v:
Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, 2005..
We are developing a highly sensitive surface acoustic wave (SAW) sensor system for biomedical and industrial applications. One of the key components of such a system is the signal read-out unit based on digital phase detection, which is needed to qua