Publikováno v:
Medical physics. 39(6Part28)
Purpose: To develop a phantom and measurement protocol for quantifying spatial accuracy of an MR imaging system over its entire imaging volume. Methods: The measurement protocol is comprised of a phantom, a set of MR sequence parameters for imaging t
Autor:
Joseph K. Maier, Bruce D. Collick, Robert D. Peters, Kevin F. King, Gaohong Wu, Dan Xu, R. Scott Hinks
Publikováno v:
Magnetic Resonance in Medicine. 70:1293-1305
Purpose The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically ha
Autor:
Dan, Xu, Joseph K, Maier, Kevin F, King, Bruce D, Collick, Gaohong, Wu, Robert D, Peters, R Scott, Hinks
Publikováno v:
Magnetic resonance in medicine. 70(5)
The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically have signi
Autor:
Yiping Du, H. Glenn Reynolds, Xiaohong Joe Zhou, Matt A. Bernstein, Jason A. Polzin, Joseph K. Maier
Publikováno v:
Magnetic resonance in medicine. 39(4)
When a linear magnetic field gradient is used, spatially higher-order magnetic fields are produced to satisfy the Maxwell equations. It has been observed that the higher-order magnetic field produced by the readout gradient causes axial echo planar i
Autor:
Joseph K. Maier, R. C. Wright, Anna E. Holsinger, Farhad Farzaneh, Roger C. Grimm, Stephen J. Riederer
Publikováno v:
Magnetic resonance in medicine. 14(3)
We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, w
Publikováno v:
Magnetic Resonance Imaging. 11:XXVII-XXVIII
Publikováno v:
Radiology. 147:859-862
Temporal filtering methods were applied to iodine signal-to-noise ratio (SNR) restoration in intravenous hybrid subtraction digital subtraction angiography (DSA). For equal detected exposure rates hybrid subtraction had approximately 35% of the SNR o
Publikováno v:
Medical Physics. 10:209-217
The technical characteristics of a new digital fluorographic image processing method called matched filtering are presented. This technique, a type of extensive temporal integration, takes a weighted sum of images acquired during passage of a contras
Publikováno v:
Investigative radiology. 19(5)
Using computer calculations and assumed contrast bolus curves, several aspects of the application of temporal integration methods and matched filtering to intravenous digital subtraction angiography (IV-DSA) were studied. The topics included the impr
Publikováno v:
Investigative Radiology. 18:S10