Zobrazeno 1 - 10
of 31
pro vyhledávání: '"José Ignacio Sarasúa"'
Autor:
José Ignacio Sarasúa, Juan Ignacio Pérez-Díaz, Guillermo Martínez-Lucas, Daniel Fernández-Muñoz
Publikováno v:
Frontiers in Energy Research, Vol 9 (2021)
This study presents a novel approach to calculate the load to be shed in El Hierro isolated power system in generation tripping events. The proposed shedding law is based on a linear regression model. The regression model is obtained by means of offl
Externí odkaz:
https://doaj.org/article/a46397cd29a64ba7b3f88d1028d39224
Publikováno v:
Energies, Vol 8, Iss 12, Pp 13559-13575 (2015)
This paper analyses different control strategies for the speed control loop of a variable-speed pump-turbine unit equipped with a doubly fed induction generator, operating in generating mode in an isolated power system with high penetration of interm
Externí odkaz:
https://doaj.org/article/811dfe70945c40e1bfba641e34edc0de
Autor:
José Ignacio Sarasúa, Guillermo Martínez-Lucas, Carlos A. Platero, José Ángel Sánchez-Fernández
Publikováno v:
Energies, Vol 11, Iss 11, p 2865 (2018)
Frequency control is one of the most critical tasks in isolated power systems, especially in high renewable penetration scenarios. This paper presents a new hydropower pumped-storage dual control strategy that combines variable-speed-driven pumps and
Externí odkaz:
https://doaj.org/article/74ab966aa5694ef8b91107a8f1972903
Publikováno v:
Energies, Vol 11, Iss 1, p 239 (2018)
Currently, some small islands with high wind potential are trying to reduce the environmental and economic impact of fossil fuels by using renewable resources. Nevertheless, the characteristics of these renewable resources negatively affect the quali
Externí odkaz:
https://doaj.org/article/21b133ddadd649248e25dc045f3fe112
Autor:
José Ignacio Sarasúa, Paz Elías, Guillermo Martínez-Lucas, Juan Ignacio Pérez-Díaz, José Román Wilhelmi, José Ángel Sánchez
Publikováno v:
The Scientific World Journal, Vol 2014 (2014)
Run-of-river hydropower plants usually lack significant storage capacity; therefore, the more adequate control strategy would consist of keeping a constant water level at the intake pond in order to harness the maximum amount of energy from the river
Externí odkaz:
https://doaj.org/article/1ad07b69755848568bfa5210ded72ad2
Publikováno v:
Energies, Vol 16, Iss 9, p 3828 (2023)
The demand for energy storage systems is rising together with the proportion of renewable energy sources (RES) in power systems. The highest capacity among the various energy storage systems in power systems is provided by pumped-storage hydropower (
Externí odkaz:
https://doaj.org/article/c67d2f7e2596442e8011afbed7d819a5
Publikováno v:
Frontiers in Energy Research, ISSN 2296-598X, 2021-09-06, Vol. 9
Frontiers in Energy Research, Vol 9 (2021)
Archivo Digital UPM
Universidad Politécnica de Madrid
Frontiers in Energy Research, Vol 9 (2021)
Archivo Digital UPM
Universidad Politécnica de Madrid
This study presents a novel approach to calculate the load to be shed in El Hierro isolated power system in generation tripping events. The proposed shedding law is based on a linear regression model. The regression model is obtained by means of offl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7270bc6b669744100c1f6d317a88a7a5
http://oa.upm.es/68458/
http://oa.upm.es/68458/
Autor:
Guillermo Martínez-Lucas, Giovanna Cavazzini, Giorgio Pavesi, Guido Ardizzon, José Ignacio Sarasúa, Manuel Chazarra, Juan I. Pérez-Díaz
Publikováno v:
Renewable Energy, ISSN 0960-1481, 2019, Vol. 133
Archivo Digital UPM
Universidad Politécnica de Madrid
Archivo Digital UPM
Universidad Politécnica de Madrid
The upgrade of a pumped-storage power plant (PSPP) to allow variable speed operation offer several advantages in pumping and generating modes. However, in pumping mode at part load, both pressure and torque pulsations develop in the pump turbine runn
Autor:
Ángel Molina García, Guillermo Martínez de Lucas, José Ignacio Sarasúa, Ana Fernández Guillamón
Publikováno v:
Renewable Energy, ISSN 0960-1481, 2021-12, Vol. 180
Archivo Digital UPM
Universidad Politécnica de Madrid
Archivo Digital UPM
Universidad Politécnica de Madrid
Wind speed fluctuations and the lack of Variable Speed Wind Turbines (VSWTs) synchronous inertia make difficult grid frequency control, mainly in isolated power systems with high penetration of wind energy. To solve this drawback, a combined wind-hyd
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a7fa0fa920dc68e6345a8ffbc519e708
https://oa.upm.es/68552/
https://oa.upm.es/68552/
Autor:
José Ignacio Sarasúa, Sergio Martinez, Juan I. Pérez-Díaz, Guillermo Martínez-Lucas, Danny Ochoa
Publikováno v:
Electronics
Volume 9
Issue 6
Electronics, ISSN 2079-9292, 2020-05-28, Vol. 9, No. 6
Archivo Digital UPM
Universidad Politécnica de Madrid
Electronics, Vol 9, Iss 901, p 901 (2020)
Volume 9
Issue 6
Electronics, ISSN 2079-9292, 2020-05-28, Vol. 9, No. 6
Archivo Digital UPM
Universidad Politécnica de Madrid
Electronics, Vol 9, Iss 901, p 901 (2020)
With high levels of wind energy penetration, the frequency response of isolated power systems is more likely to be affected in the event of a sudden frequency disturbance or fluctuating wind conditions. In order to minimize excessive frequency deviat