Autor:
Konstantinos Diamantis, Tom Anderson, Jorgen Arendt Jensen, Paul A. Dalgarno, Vassilis Sboros
Publikováno v:
IEEE Access, Vol 7, Pp 6297-6309 (2019)
Super-resolution ultrasound mostly uses image-based methods for the localization of single scatterers. These methods are largely based on the center of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer locali
Externí odkaz:
https://doaj.org/article/04bf9d33e457440ba4019c0c15b48786
Publikováno v:
Jørgensen, L T, Traberg, M S, Stuart, M B & Jensen, J A 2022, ' Performance Assessment of Row-Column Transverse Oscillation Tensor Velocity Imaging using Computational Fluid Dynamics Simulation of Carotid Bifurcation Flow ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 4, pp. 1230-1242 . https://doi.org/10.1109/TUFFC.2022.3150106
In this work the accuracy of row-column tensor velocity imaging, i.e., 3-D vector flow imaging in 3-D space over time, is quantified on complex, clinically relevant flow. The quantification is achieved by transferring flow simulated using computation
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Borislav G. Tomov, Nathalie Sarup Panduro, Charlotte Mehlin Sorensen, Matthias Bo Stuart
Publikováno v:
Jensen, J A, Schou, M, Ommen, M L, Steenberg, K, Thomsen, E V, Tomov, B G, Panduro, N S, Sorensen, C M & Stuart, M B 2022, Synthetic Aperture High Quality B-mode Imaging with a Row-Column Array Compared to Linear Array Imaging . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9957973
Row-column (RC) matrix probes can yield 3-Dvolumetric imaging using a number of receiving elements similarto traditional linear arrays for commercial scanners. Some doubtshave, however, been raised on the B-mode image quality ofRC probes. It is hypot
Autor:
Iman Taghavi, Mostafa Amin-Naji, Mikkel Schou, Martin Lind Ommen, Kitty Steenberg, Niels Bent Larsen, Erik Vilain Thomsen, Jorgen Arendt Jensen
Publikováno v:
2022 IEEE International Ultrasonics Symposium (IUS).
Autor:
Sebastian Kazmarek Praesius, Matthias Bo Stuart, Mikkel Schou, Bernd Dammann, Hans Henrik Brandenborg Sorensen, Jorgen Arendt Jensen
Publikováno v:
Præsius, S K, Stuart, M B, Schou, M, Dammann, B, Brandenborg Sørensen, H H & Jensen, J A 2022, Real-Time Super-Resolution Ultrasound Imaging using GPU Acceleration . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, pp. 1-4, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9957589
The method SUper-Resolution ultrasound imaging using the Erythrocytes as targets (SURE) is fully non-invasive, and can reliably visualize vessels with sizes down to 50 μm (1/3 of the wavelength) from a few seconds of data acquisition. Ideally, the a
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::036708badd144b7cb5b3bff065ce8a14
https://orbit.dtu.dk/en/publications/b5d43342-03c8-4348-aca2-6d1cf5e1202b
https://orbit.dtu.dk/en/publications/b5d43342-03c8-4348-aca2-6d1cf5e1202b
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Lasse Thurmann Jorgensen, Borislav G. Tomov, Matthias Bo Stuart, Marie Sand Traberg, Iman Taghavi, Sigrid Huesebo Oygaard, Martin Lind Ommen, Kitty Steenberg, Erik Vilain Thomsen, Nathalie Sarup Panduro, Michael Bachmann Nielsen, Charlotte Mehlin Sorensen
Publikováno v:
Jensen, J A, Schou, M, Jorgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Oygaard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sorensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Jensen, J A, Schou, M, Jørgensen, L T, Tomov, B G, Stuart, M B, Traberg, M S, Taghavi, I, Øygard, S H, Ommen, M L, Steenberg, K, Thomsen, E V, Panduro, N S, Nielsen, M B & Sørensen, C M 2022, ' Anatomic and Functional Imaging using Row-Column Arrays ', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 69, no. 10, 9830770, pp. 2722-2738 . https://doi.org/10.1109/TUFFC.2022.3191391
Row-column (RC) arrays have the potential to yield full 3-D ultrasound imaging with a greatly reduced number of elements compared to fully populated arrays. They, however, have several challenges due to their special geometry. This review article sum
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d1a139a50010404bebd1817b624c7df8
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
https://curis.ku.dk/portal/da/publications/anatomic-and-functional-imaging-using-rowcolumn-arrays(cd7494c5-36a5-4ee1-93da-9a89cbe0b554).html
Autor:
Jorgen Arendt Jensen, Mikkel Schou, Sofie Bech Andersen, Borislav G. Tomov, Stinne Byrholdt Sogaard, Charlotte Mehlin Sorensen, Michael Bachmann Nielsen, Carsten Gundlach, Hans Martin Kjer, Anders Bjorholm Dahl, Matthias Bo Stuart
Publikováno v:
Jensen, J A, Schou, M, Andersen, S B, Tomov, B G, Søgaard, S B, Sorensen, C M, Nielsen, M B, Gundlach, C, Kjer, H M, Dahl, A B & Stuart, M B 2022, In Vivo Super Resolution Ultrasound Imaging using the Erythrocytes-SURE . in Proceedings of 2022 IEEE International Ultrasonics Symposium . IEEE, 2022 IEEE International Ultrasonics Symposium, Venice, Italy, 10/10/2022 . https://doi.org/10.1109/IUS54386.2022.9958236
Current super resolution imaging is conducted using ultrasound contrast agents, where a sparse distribution ofbubbles must be employed to separate individual targets. Thesparse targets make the acquisition time long in the range of1 to 10 minutes, an
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::75b17aacbeb3fe008314423b5c842e0c
https://orbit.dtu.dk/en/publications/2e8e67a1-b3b4-471b-90dc-d4c0808d8ab2
https://orbit.dtu.dk/en/publications/2e8e67a1-b3b4-471b-90dc-d4c0808d8ab2
Autor:
Masoud Meskin, Philip Alexander Starkey, Alexander Emil Kaspersen, Steffen Ringgaard, Signe Gram Sand, Jens Vinge Nygaard, Jørgen Arendt Jensen, Marie Sand Traberg, Peter Johansen
Publikováno v:
Scientific Reports, Vol 14, Iss 1, Pp 1-19 (2024)
Abstract The left atrium (LA) hemodynamic indices hold prognostic value in various cardiac diseases and disorders. To understand the mechanisms of these conditions and to assess the performance of cardiac devices and interventions, in vitro models ca
Externí odkaz:
https://doaj.org/article/4273c26aed2b492cb03f6c4422e8d62e
Autor:
Konstantinos Diamantis, Tom Anderson, Jorgen Arendt Jensen, Paul A. Dalgarno, Vassilis Sboros
Publikováno v:
Diamantis, K, Anderson, T, Jensen, J A, Dalgarno, P & SBOROS, VASSILIS 2018, ' Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging ', IEEE Access, vol. 7, 2169-3536, pp. 6297-6309 . https://doi.org/10.1109/ACCESS.2018.2889425
Diamantis, K, Anderson, T, Jensen, J A, Dalgarno, P A & Sboros, V 2019, ' Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging ', IEEE Access, vol. 7, no. 1, pp. 6297-6309 . https://doi.org/10.1109/ACCESS.2018.2889425
IEEE Access, Vol 7, Pp 6297-6309 (2019)
Diamantis, K, Anderson, T, Jensen, J A, Dalgarno, P A & Sboros, V 2019, ' Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging ', IEEE Access, vol. 7, no. 1, pp. 6297-6309 . https://doi.org/10.1109/ACCESS.2018.2889425
IEEE Access, Vol 7, Pp 6297-6309 (2019)
Super-resolution ultrasound mostly uses image-based methods for the localization of single scatterers. These methods are largely based on the center of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer locali
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::a991d334028ee1009fbec417099d7600
https://hdl.handle.net/20.500.11820/268d494d-2f8c-49e7-bca4-57f6efbb175c
https://hdl.handle.net/20.500.11820/268d494d-2f8c-49e7-bca4-57f6efbb175c
Autor:
Ramin, Moshavegh, Kristoffer Lindskov, Hansen, Hasse, Moller-Sorensen, Michael Bachmann, Nielsen, Jorgen Arendt, Jensen
Publikováno v:
IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 66(2)
This paper proposes an automatic method for accurate detection and visualization of B-lines in ultrasound lung scans, which provides a quantitative measure for the number of B-lines present. All the scans used in this study were acquired using a BK30