Hans J. C. Klamer, JoopL.M. Hermens, Leen A. Villerius, EricM.J. Verbruggen, UdoA.Th. Brinkman
Publikováno v:
Verbruggen, E M J, Klamer, H J C, Villerius, L, Brinkman, U A T & Hermens, J L M 1999, ' Gradient elution reversed-phase high-performance liquid chromatography for fractionation of complex mixtures of organic micropollutants according to hydrophobicity using isocratic retention parameters. ', Journal of Chromatography A, vol. 835, pp. 19-27 . https://doi.org/10.1016/S0021-9673(97)90065-0
Journal of Chromatography A, 835, 19-27. Elsevier
Journal of Chromatography A, 835, 19-27. Elsevier
Gradient elution RP-HPLC is used as a suitable method to infer the hydrophobicity values (log K(ow)) of components in complex samples. In this study, the slope (S) and the intercept (log k(w)) of the linear relationship between the logarithm of the r