Jong-ian Tsai, 蔡忠諺
92
During the three decades, the torsional impact on turbine-generator sets due to power system disturbances has been extensively discussed in many research works. However, most of them are focused on the fatigue damage of turbine shafts due to
During the three decades, the torsional impact on turbine-generator sets due to power system disturbances has been extensively discussed in many research works. However, most of them are focused on the fatigue damage of turbine shafts due to
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/61034261955865217022
Publikováno v:
International Journal of Hydrogen Energy. 36:13575-13586
Three-dimensional models of a plate methanol steam micro-reformer and a methanol catalytic combustor with parallel flow fields and serpentine flow fields have been established. The effects of the flow field design and the fuel flow rate on the methan
Autor:
Jong-Ian Tsai
Publikováno v:
European Transactions on Electrical Power. 19:1065-1081
The long-term effect of noncharacteristic harmonic currents arising from a slip energy recovery drive (SERD) on the fatigue life expenditure in turbine-generator blades is presented in this paper. Since the SERD converter can be rated at a fraction o
Autor:
Jong-Ian Tsai
Publikováno v:
Electric Power Systems Research. 77:1619-1626
This paper presents a new single-pole switching scheme for depressing turbine–generator blade torsional torque. Since the single-phase fault occurs more frequently in power line accidents, there are many advantages on stability and reliability by u
Autor:
Jong-Ian Tsai
Publikováno v:
Electrical Engineering. 89:377-387
Due to more various power disturbances occurring in a power system involving a HVDC link, the turbine generator shafts and/or blades are more prone to damage than in general HVAC systems. In this paper, a new mechanical damper scheme based on partici
Publikováno v:
Electric Power Systems Research. 65:135-147
The long-term effect of noncharacteristic harmonic currents in asynchronous HVDC links on fatigue life expenditure in turbine–generator blades is studied in this paper. Because the frequencies of the two main harmonic current terms are subsynchrono
Autor:
Gwo-Ching Liao, Jong-Ian Tsai
Publikováno v:
Web of Science
With the decreasing of the fossil energy source and the increasing of load demand, making full use of clean and renewable energy, Distributed Generation (DG) technologies gain more and more attentions. Smart MicroGrid (SMG) integrates the advantages
Publikováno v:
2012 Asia-Pacific Power and Energy Engineering Conference.
Wind energy is one of the most popular and economic renewable energy generations. According to the statistics, there is about 3GW wind energy power potentially in Taiwan. If the grid-connected wind turbine generator is subjected to the network faults
Publikováno v:
2011 6th IEEE Conference on Industrial Electronics and Applications.
This paper proposes a method to find the equivalent circuit parameters, moment of inertia, and friction coefficient of an induction machine. The reference data include time-varied signals of voltage, current and rotor speed. By the time-varied voltag
Publikováno v:
2010 8th IEEE International Conference on Industrial Informatics.
This paper offers a new method to measure the operational condition of the induction motor. The acoustic signal is measured for analysis. It can not only still be detected normally when other signals can't, but it also has the function of motor fault