Zobrazeno 1 - 10
of 11
pro vyhledávání: '"John M. Pristas"'
Autor:
Carla J. Nastala, Robert L. Kormos, Bartley P. Griffith, Stephen Winowich, Peer M. Portner, Eve A. Conner, Harvey S. Borovetz, Jeannie Gifford, John M. Pristas
Publikováno v:
ASAIO Journal. 41:M539-M543
Between September 1984 and April 1995, the Novacor left ventricular assist system (LVAS) has provided more than 13,000 days of mechanical circulatory support to cardiac transplant candidates in the United States and Europe. The duration of support of
Autor:
Yuji Miyamoto, Bartley P. Griffith, John M. Pristas, Robert L. Kormos, Harvey S. Borovetz, Thomas A. Gaisor, John M. Armitage, Robert L. Hardesty
Publikováno v:
Artificial Organs. 14:454-457
The interrelationships between hemodynamic variables including right ventricular (RV) performance with filling/ejection dynamics of the Novacor left ventricular assist system (LVAS) were determined in 10 of 11 patients who received LVAS as a bridge t
Publikováno v:
The Annals of Thoracic Surgery. 61:396-398
Background. There is interest in expanding ventricular assist device use from short-term bridging to transplantation to long-term and permanent support. Methods. We have reviewed the outcome of 162 patients who had a mechanical bridge to transplantat
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 47(3)
As Novacor LVAS recipients continue to be discharged from the hospital to await cardiac transplantation, an increasing number of patients either need or desire to use air transportation. To date, two test experiences have been reported with the Novac
Autor:
Carla J. Nastala, Robert L. Kormos, Mary Amanda Dew, R. D. Canning, S. Winowich, John M. Pristas, Griffith Bp
Publikováno v:
Quality of Life and Psychosomatics ISBN: 9783642959813
Candidates for heart transplantation face increasingly lengthy waits for donor hearts. In the United States, candidates may wait for well over 12 months (United Network of Organ Sharing statistics for 1994), and during this period, life-threatening d
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::135c6b168f107a5ce4dca0e7777aa826
https://doi.org/10.1007/978-3-642-95979-0_2
https://doi.org/10.1007/978-3-642-95979-0_2
Publikováno v:
The Annals of thoracic surgery. 61(1)
Six patients supported by the Baxter Novacor left ventricular assist system have been discharged during the period of mechanical circulatory support at the University of Pittsburgh Medical Center. Benefits of discharge couple qualify of life improvem
Publikováno v:
Chest. 99(6)
Following a massive myocardial infarction culminating in cardiogenic shock, a 61-year-old man underwent implantation of the Jarvik 70-ml total artificial heart. On the fifth postoperative day, hemodynamic instability coupled with subtle radiographic
Autor:
Robert L. Hardesty, Harvey S. Borovetz, Robert L. Kormos, Bartley P. Griffith, John M. Armitage, John M. Pristas, James F. Antaki, Thomas A. Gasior
Publikováno v:
The Annals of thoracic surgery. 49(2)
Between July 1987 and March 1989, 11 patients underwent left ventricular support with the Novacor left ventricular assist system irrespective of apparent degree of right ventricular failure. The first 2 patients died of multisystem organ failure whil
Publikováno v:
Perfusion. 5(3)
As the number of cardiac transplant centres increases, there is an associated decrease in the availability of donor organs per centre. Subsequently, hospitals are utilizing cardiac assist systems (total artificial heart and ventricular assist devices
Autor:
Kenneth N. Litwak, Robert D. Dowling, Lauren S Unger, Laman A. Gray, John M. Pristas, David C. Borzelleca, Kenji Yamazaki
Publikováno v:
ASAIO Journal. 52:48A