Zobrazeno 1 - 10
of 10
pro vyhledávání: '"John Dimeff"'
Publikováno v:
Review of Scientific Instruments. 33:804-811
A new transducer has been developed that will measure pressure over a wide range by sensing the damping of a vibrating diaphragm immersed in the gas whose pressure is being measured. It is capable of measuring pressures from approximately 10−5 to 2
Autor:
John Dimeff, Dean R. Harrison
Publikováno v:
Review of Scientific Instruments. 44:1468-1472
A new diode‐quad transducer bridge circuit has been developed which features: (1) a high output that is independent of excitation frequency and waveform; (2) a fractional capacitance (ΔC/Co) resolution of 4.4 × 10−8 at a bandwidth of 10–30 Hz
Publikováno v:
The Journal of the Acoustical Society of America. 39:849-855
The transverse motion of a tensioned string driven parametrically by a moving end support is examined both analytically and experimentally. The conditions required to linearize the equations of motion for vibrations over a large‐amplitude range at
Publikováno v:
IEEE Spectrum. 4:98-104
A simple model of communications capability projected for the mid-1970s is formulated. The spectral dependence of the future state of the art is examined in terms of antennas, noise, diffraction effects, etc. The model suggests that the frequency spe
Publikováno v:
Review of Scientific Instruments. 37:1562-1566
The results of space experiments designed to determine the intensity and energy distribution of the solar plasma have been somewhat ambiguous because of the inability to provide separate measurements for the H+ and He++ components of the plasma strea
Autor:
James W. Lane, John Dimeff
Publikováno v:
Review of Scientific Instruments. 35:666-668
Vibrating-membrane transducer in a circuit can measure current below 10 to-the-minus 17 ampere. This electrometer has a high conversion gain and a minimum internal power consumption.
Publikováno v:
Medicalbiological engineering. 12(3)
Respiratory failure for as little as 2 min can cause permanent brain damage or death by suffocation. Infants, small children or comatose adults who have had tracheal tubes surgically implanted are vulnerable to this problem, and therefore require con
Autor:
Jackson R. Stalder, Alvin Seiff, J. H. Spiegel, Benjamin H. Beam, H. Julian Allen, John Dimeff
Publikováno v:
High Speed Problems of Aircraft and Experimental Methods
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::fd7925a02f463b40c5d745a6d9b990ed
https://doi.org/10.1515/9781400875030-013
https://doi.org/10.1515/9781400875030-013
Publikováno v:
Medicalbiological engineering. 7(6)
Mass measuring device used on biological specimens in zero gravity environment, determining normal and disturbed physiological mechanisms
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.