Publikováno v:
Medical Physics. 45:5564-5576
PURPOSE This work seeks to investigate new methods to determine the absorbed dose to water from kilovoltage x rays. Current methods are based on measurements in air and rely on correction factors in order to account for differences between the photon
Publikováno v:
Medical Physics. 44:311-320
Purpose To perform an in-air air-kerma strength (Sĸ) calibration of the Bebig model Ir2.A85-2 192Ir high-dose rate (HDR) brachytherapy source manufactured by Mallinckrodt Medical (Wester-duinweg, Germany) with the NIST-traceable seven-distance techn
Publikováno v:
Medical Physics. 43:2141-2152
Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specificati
Publikováno v:
Brachytherapy. 14:405-408
Purpose To propose a modification of the current dose calculation formalism introduced in the Task Group No. 43 Report (TG-43) to accommodate an air-kerma rate standard for electronic brachytherapy sources as an alternative to an air-kerma strength s
Publikováno v:
Medical physics. 44(3)
We would like to thank Dr. Brivio et al. [Med. Phys.] for their comment on our recent paper. Miller et al. [Med. Phys. 43 (2016) 2141-2152] determined the primary cause of voltage-dependent polarity effects in microchambers to be a potential differen
Publikováno v:
Medical physics. 44(1)
To perform an in-air air-kerma strength (SK) calibration of the Bebig model Ir2.A85-2 192Ir high-dose rate (HDR) brachytherapy source manufactured by Mallinckrodt Medical (Westerduinweg, Germany) with the NIST-traceable seven-distance technique estab
Publikováno v:
Medical physics. 44(2)
Purpose To investigate ion recombination and polarity effects in scanning and microionization chambers when used with digital electrometers and high-dose-rate linac beams such as flattening-filter-free (FFF) fields, and to compare results against con
Publikováno v:
Medical physics. 43(5)
Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a r
Publikováno v:
Medical Physics. 38:6721-6729
Purpose: To perform a comparison of the interim air-kerma strength standard for high dose rate (HDR)192Ir brachytherapy sources maintained by the University of Wisconsin Accredited DosimetryCalibration Laboratory (UWADCL) with measurements of the var
Publikováno v:
Medical Physics. 38:5771-5777
Purpose: Gafchromic® EBT2 film has a yellow marker dye incorporated into the active layer of the film that can be used to correct the film response for small variations in thickness. This work characterizes the effect of the marker-dye correction on