Zobrazeno 1 - 10
of 277
pro vyhledávání: '"Jiyan, Zou"'
Publikováno v:
CSEE Journal of Power and Energy Systems, Vol 8, Iss 1, Pp 249-257 (2022)
Externí odkaz:
https://doaj.org/article/4f7b2a79805d4eeb8eaa2f87e182f208
Publikováno v:
High Voltage, Vol 6, Iss 2, Pp 328-336 (2021)
Abstract To develop high‐voltage‐pulsed power switches with better performances, a multi‐gap laser‐triggered vacuum switch is proposed in this study. Based on established test prototype for double‐gap laser‐triggered vacuum switch, closin
Externí odkaz:
https://doaj.org/article/cede9104085143009915a435feb9eb67
Publikováno v:
IEEE Access, Vol 8, Pp 194719-194728 (2020)
The vacuum interrupter is widely used due to the advantages of no arc-extinguishing medium and high insulation strength. However, the arc voltage generated by the commonly used CuCr contacts is low. In hybrid DC circuit breakers (DCCB), hybrid automa
Externí odkaz:
https://doaj.org/article/f4daa434be6448019f16338fce93b908
Publikováno v:
AIP Advances, Vol 12, Iss 2, Pp 025014-025014-10 (2022)
Multi-break vacuum circuit breakers (VCBs) is an important research direction for scaling VCBs up to a higher voltage level. A VCB module with an integrated operation of double-break is designed to increase synchronization of multi-break VCBs, and th
Externí odkaz:
https://doaj.org/article/b7ebb589453b42e09a80f6c2892cf4a2
Publikováno v:
CSEE Journal of Power and Energy Systems, Vol 5, Iss 4, Pp 545-552 (2019)
Constrained by the characteristics of neutral sections (NS) and traditional vacuum circuit breakers, previous phase-controlled strategies have a long power supply dead time, it is difficult to realize a continuous power supply to the auxiliary power
Externí odkaz:
https://doaj.org/article/d14b58b714f141cfaa62c281c846b384
Publikováno v:
IEEE Transactions on Plasma Science. 51:572-580
Publikováno v:
Energies, Vol 14, Iss 22, p 7466 (2021)
To ensure the reliability of power supply, a dual power supply structure appears in the power distribution system. Power supply switching is a complex physical process. This paper presents a novel model of electromechanical contactors. This model can
Externí odkaz:
https://doaj.org/article/3c6305b804644f05bb7a0cdb5b47f8b4
Publikováno v:
The Journal of Engineering (2019)
Here, a DC vacuum arc interruption test based on the hybrid high-speed actuator and the method of commutation is carried out in the synthetic loop system. The safe stroke is one of the basic breaking parameters. The minimum safe stroke directly deter
Externí odkaz:
https://doaj.org/article/8bf7575a6b0249ecad6f52391e9d1cd6
Autor:
Dequan Wang, Minfu Liao, Rufan Wang, Tenghui Li, Jun Qiu, Jinjin Li, Xiongying Duan, Jiyan Zou
Publikováno v:
Energies, Vol 13, Iss 18, p 4823 (2020)
Vacuum arc commutation is an important process in natural-commutate hybrid direct current (DC) circuit breaker (NHCB) interruption, as the duration of vacuum arc commutation will directly affect the arcing time and interrupting time of NHCB. In this
Externí odkaz:
https://doaj.org/article/95a3f7cb5d424c73936fa0dfa03cfced
Publikováno v:
High Voltage, Vol 6, Iss 2, Pp 328-336 (2021)
To develop high‐voltage‐pulsed power switches with better performances, a multi‐gap laser‐triggered vacuum switch is proposed in this study. Based on established test prototype for double‐gap laser‐triggered vacuum switch, closing process