Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Jing-Rui Tian"'
Publikováno v:
Canadian Mathematical Bulletin. 61:768-786
The study of chaotic vibration for multidimensional PDEs due to nonlinear boundary conditions is challenging. In this paper, we mainly investigate the chaotic oscillation of a two-dimensional non-strictly hyperbolic equation due to an energy-injectin
Publikováno v:
Applied Mechanics and Materials. 540:110-113
With increasing of the evaporating temperature, the two stage compression cycle with an internal exchanger’s COP has an increasing trend. In addition, R744 achieves the highest COP, and the R12 achieves the minimum level. With increasing of the hig
Publikováno v:
Advanced Materials Research. :2774-2777
In range of high pressure, the performance of single stage cycle with an expander (SCE) is better than the cycle with a throttling valve (SCV). With increasing of the evaporating temperature or decreasing outlet temperature of condenser, the performa
Publikováno v:
Advanced Materials Research. :2790-2793
In range of high pressure, the performance of single stage cycle with an expander (SCE) is better than the cycle with a throttling valve (SCV). With increasing of the evaporating temperature or decreasing outlet temperature of condenser, the performa
Publikováno v:
Advanced Materials Research. :2679-2682
With increasing of high pressure, the performances of all kinds refrigerants except for R744 are all declined and transcritical R744 compression cycle has an optimum high pressure. With increasing of the evaporating temperature, all cycle COP is an i
Autor:
Hong Li Wang, Jing Rui Tian
Publikováno v:
Advanced Materials Research. :1064-1067
In range of high pressure, the performance of single stage cycle with an expander (SCE) is better than the cycle with a throttling valve (SCV) and an internal heat exchanger (SCV+IHX). With increasing of the evaporating temperature or decreasing outl
Publikováno v:
Advanced Materials Research. :1998-2002
In range of high pressure, the performance of two stage compression cycle with an expander (TSCE+IC) is better than the two stage cycle with an intercooler (TSCC+IC). In the cycle (TSCE+IC), the optimum discharge temperature is 42°C and the highest
Publikováno v:
Advanced Materials Research. :1860-1865
Based on thermodynamic principles, the coupled systems performance of the Rankine cycle and the transcritical CO2compression cycles with a throttle valve and the cycle with an expander were analyzed, respectively. The results show that the correspond
Publikováno v:
Advanced Materials Research. :2438-2442
With the question of Ozone Depression Potential and Global Warming Potential popping out day by day, the Freon refrigerant alternative has become one of the current research contents of refrigerant. Based on the given Freon refrigerant R22, R134a and