Sean Thomas Mckenna, N. Jones, John Harbottle, Jim L. D. Glockling, T. Richard Hull, Gabrielle Peck, Anna A. Stec
Publikováno v:
Journal of hazardous materials. 403
The toxic smoke production of four rainscreen façade systems were compared during large-scale fire performance testing on a reduced height BS 8414 test wall. Systems comprising 'non-combustible' aluminium composite material (ACM) with polyisocyanura
The Grenfell Tower fire has brought the regulatory system that permitted combustible materials on high-rise buildings in England into question. At the heart of that system is the BS 8414 test, and the BR 135 criteria used to demonstrate compliance wi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5dbf6659e1032d919b66ec38eef41739
https://clok.uclan.ac.uk/34079/1/Schulz_et_al-2020-Fire_Technology.pdf
https://clok.uclan.ac.uk/34079/1/Schulz_et_al-2020-Fire_Technology.pdf
Autor:
Jim L. D. Glockling, Gabrielle Peck, Sean Thomas Mckenna, T. Richard Hull, John Harbottle, N. Jones, Anna A. Stec
Publikováno v:
Journal of Hazardous Materials. 403:123894
Four reduced-height (5 m) BS 8414-1 facade flammability tests were conducted, three having mineral-filled aluminium composite material (ACM-A2) with polyisocyanurate (PIR) and phenolic (PF) foam and stone wool (SW) insulation, the fourth having polye