Engineering Failure Analysis. 16:1794-1804
A 150 MW gas turbine experienced a forced break down because of extremely high vibrations and subsequent output power reduction down to almost zero. Before the break down, the turbine was operated by approximately 1800 hours in intermittent mode, wit
Publikováno v:
Journal of Failure Analysis and Prevention. 5:26-32
This paper presents an investigation into causes of failure of geothermal steam turbine blades. Several L-0 blades of geothermal steam turbines of 110 MW capacity suffered failures, causing forced outages of the turbines. To assess the causes of fail
Publikováno v:
Volume 3: Heat Transfer, Parts A and B.
In this paper the distributions of heat transfer and thermal mechanical stress in the metal blade surface are investigated. The stream that surrounds the blade was considered at the time that the cooling airflow runs through the blade interior. Cooli
Autor:
Jesu´s Nebradt, Fernando Cadena, Hugo Lara, Diganta Narzary, Fernando Z. Sierra Espinosa, J. Kubiak, Je-Chin Han, Sarah A. Blake, Areli Uribe Portugal
Publikováno v:
Volume 4: Heat Transfer, Parts A and B.
Temperature and flow rate of combustion gases and cooling stream are essential conditions for blade integrity in gas turbines. Since the combustion products pass directly to the first stage of blades high thermal stresses can develop, so the temperat
Publikováno v:
Volume 2: Controls, Diagnostics and Instrumentation; Cycle Innovations; Electric Power.
The turbine rotors experience high-thermo mechanical stresses caused by requirements of their operation. These cause mechanical damage (fatigue) that is accumulated according to the frequency with which the different ways of operation (cold, warm or