Zobrazeno 1 - 10
of 26
pro vyhledávání: '"Jeroen Kortsmit"'
Publikováno v:
Cardiovascular Revascularization Medicine. 43:123-129
To evaluate safety and accuracy of stent placement by Stent Positioning Assistance System (SPAS), an innovative device that allows for mm-precise manipulation and placement of stents in percutaneous coronary interventions (PCI).In PCI, controlled ste
Bleeding complications in patients undergoing cardiac surgery are common. The clinician must assimilate multiple sources of monitoring information, make rational decisions on the etiology of the bleeding, and then formulate a treatment strategy. Clin
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::96dda5db5a38cd7b5b48f132fc21f29f
Autor:
Benno H. W. Hendriks, Manfred Müller, Gerald W. Lucassen, Henricus J. C. M. Sterenborg, Jeroen Kortsmit, Theo J.M. Ruers, Marjolein Van Der Voort, Andrea J.R. Balthasar, Geert-Jan van Geffen, Thorsten Steinfeldt, Torre Michelle Bydlon, G.C. Langhout
Publikováno v:
Lasers in Surgery and Medicine. 50:253-261
OBJECTIVE Identification of peripheral nerve tissue is crucial in both surgery and regional anesthesia. Recently, optical tissue identification methods are presented to facilitate nerve identification in transcutaneous procedures and surgery. Optimiz
Autor:
Gerrit C, Langhout, Torre M, Bydlon, Marjolein, van der Voort, Manfred, Müller, Jeroen, Kortsmit, Gerald, Lucassen, Andrea J R, Balthasar, Geert-Jan, van Geffen, Thorsten, Steinfeldt, Henricus J C M, Sterenborg, Benno H W, Hendriks, Theo J M, Ruers
Publikováno v:
Lasers in surgery and medicine. 50(3)
Identification of peripheral nerve tissue is crucial in both surgery and regional anesthesia. Recently, optical tissue identification methods are presented to facilitate nerve identification in transcutaneous procedures and surgery. Optimization and
Publikováno v:
Advances in biomechanics and applications. 1:41-55
Acellular intra-myocardial biomaterial injections have been shown to be therapeutically beneficial in inhibiting ventricular remodelling of myocardial infarction (MI). Based on a biventricular canine cardiac geometry, various finite element models we
Publikováno v:
International Journal for Numerical Methods in Biomedical Engineering. 29:870-884
Myocardial infarction therapies involving biomaterial injections have shown benefits in inhibiting progression towards heart failure. However, the underlying mechanisms remain unclear. A finite element model of the human left ventricle was developed
Autor:
Martin Schweiger, Volkmar Falk, Simon P. Hoerstrup, Melanie Black, Maximilian Y. Emmert, Silvia Peter, Anita Anita Driessen-Mol, Marco Stampanoni, Renier Verbeek, Marina van Doeselaar, Peter Zilla, Chad Brokopp, Mona Bracher, Jürg Grünenfelder, Jerome Robert, Jacques Scherman, Petra E. Dijkman, Thomas Franz, Peter Modregger, Frank P. T. Baaijens, Benedikt Weber, Jeroen Kortsmit, Debora Kehl, Thomas Wälchli, Bart Sanders
Publikováno v:
Biomaterials; Vol 34
Biomaterials, 34(30), 7269-7280. Elsevier
Biomaterials, 34(30), 7269-7280. Elsevier
Heart valve tissue engineering based on decellularized xenogenic or allogenic starter matrices has shown promising first clinical results. However, the availability of healthy homologous donor valves is limited and xenogenic materials are associated
Autor:
Jeroen Kortsmit, Benno H. W. Hendriks, Arnold T. M. H. van Keersop, Christian Reich, G.C. Langhout, Geert‑Jan van Geffen, Marjolein Van Der Voort, Manfred Mueller, Vishnu Vardhan Pully, Gerald W. Lucassen, Andrea J.R. Balthasar, Torre Michelle Bydlon
Publikováno v:
Journal of Translational Medicine, 13:380. BioMed Central Ltd
Journal of Translational Medicine
Journal of Translational Medicine, 13, pp. 380
Journal of Translational Medicine, 13, 380
Journal of Translational Medicine
Journal of Translational Medicine, 13, pp. 380
Journal of Translational Medicine, 13, 380
Background: Regional anesthesia has several advantages over general anesthesia but requires accurate needle placement to be effective. To achieve accurate placement, a needle equipped with optical fibers that allows tissue discrimination at the needl
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::dc3c9769f2ddb59a53b19c7f12437863
https://cris.maastrichtuniversity.nl/en/publications/dbd571c2-81fe-4619-9a1a-64413457eeca
https://cris.maastrichtuniversity.nl/en/publications/dbd571c2-81fe-4619-9a1a-64413457eeca
Publikováno v:
Tissue engineering. Part A, 16(5), 1527-1537. Mary Ann Liebert Inc.
Creating autologous tissues with on-demand and native-like biomechanical properties is the ultimate challenge in functional heart valve tissue engineering. A promising approach toward this goal is to induce development of native-like tissue structure
Publikováno v:
Annals of Biomedical Engineering, 37(3), 532-541. Springer
In heart valve tissue engineering, most bioreactors try to mimic physiological flow and operate with a preset transvalvular pressure applied to the tissue. The induced deformations are unknown and can vary during culturing as a consequence of changin