Zobrazeno 1 - 10
of 70
pro vyhledávání: '"Jeroen C.W. Hopman"'
Autor:
Kian D. Liem, W.P. de Boode, Joris Lemson, S.L.A.G. Vrancken, A Nusmeier, Jeroen C.W. Hopman, J.G. van der Hoeven, A.F.J. van Heijst
Publikováno v:
Journal of Clinical Monitoring and Computing
Journal of Clinical Monitoring and Computing, 30, 985-994
Journal of Clinical Monitoring and Computing, 30, 6, pp. 985-994
Journal of Clinical Monitoring and Computing, 30, 985-994
Journal of Clinical Monitoring and Computing, 30, 6, pp. 985-994
Contains fulltext : 168747.pdf (Publisher’s version ) (Open Access) Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside me
Autor:
S.L.A.G. Vrancken, Monika G. Looijen-Salamon, W.P. de Boode, Jeroen C.W. Hopman, Kian D. Liem, A.F.J. van Heijst
Publikováno v:
British Journal of Anaesthesia, 109, 870-8
British Journal of Anaesthesia, 109, 6, pp. 870-8
British Journal of Anaesthesia, 109, 6, pp. 870-8
Contains fulltext : 108353.pdf (Publisher’s version ) (Closed access) BACKGROUND: /st> Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in thi
Publikováno v:
Physiological Reports
Physiological Reports, 4, e12716-e12716
Physiological Reports, 4, 4, pp. e12716-e12716
Physiological Reports, 4, e12716-e12716
Physiological Reports, 4, 4, pp. e12716-e12716
Contains fulltext : 171928.pdf (Publisher’s version ) (Open Access) During positive pressure ventilation, arterial pressure variations, like the pulse pressure variation (PPV), are observed in neonates. However, the frequency of the PPV does not al
Autor:
S.L.A.G. Vrancken, Johannes G. van der Hoeven, Jeroen C.W. Hopman, Kian D. Liem, Arno van Heijst, Willem P. de Boode
Publikováno v:
Journal of Perinatal Medicine, 44, 8, pp. 925-932
Journal of Perinatal Medicine, 44, 925-932
Journal of Perinatal Medicine, 44, 925-932
Objectives: We investigated the accuracy of left-to-right shunt detection using transpulmonary ultrasound dilution (TPUD) and compared the agreement between pulmonary over systemic blood flow (Qp/Qs) ratio measured by TPUD [Qp/Qs(tpud)] and ultrasoni
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::04fe314c04e2d8ec9fe9a8bb3ee262a6
https://hdl.handle.net/2066/168744
https://hdl.handle.net/2066/168744
Autor:
W.P. de Boode, J.G. van der Hoeven, Marc H. W. A. Wijnen, Jeroen C.W. Hopman, Ronald B. Tanke, Kian D. Liem
Publikováno v:
Neonatology, 97, 124-131
Neonatology, 97, 124-31
Neonatology, 97, 2, pp. 124-131
Neonatology, 97, 2, pp. 124-31
Neonatology, 97, 124-31
Neonatology, 97, 2, pp. 124-131
Neonatology, 97, 2, pp. 124-31
Background: It remains a great challenge to measure systemic blood flow in critically ill newborns. In a former study we validated the modified carbon dioxide Fick (mCO2F) method for measurement of cardiac output in a newborn lamb model. In this new
Autor:
K. Djien Liem, Arno van Heijst, Willem P. de Boode, Ronald B. Tanke, Hans van der Hoeven, Jeroen C.W. Hopman
Publikováno v:
Pediatric Critical Care Medicine, 11, 5, pp. 616-23
Pediatric Critical Care Medicine, 11, 616-23
Pediatric Critical Care Medicine, 11, 616-23
Contains fulltext : 88270.pdf (Publisher’s version ) (Closed access) OBJECTIVE: Analysis of cerebral and systemic hemodynamic consequences of ultrasound dilution cardiac output measurements. DESIGN: : Prospective, experimental piglet study. SETTING
Publikováno v:
Pediatric Critical Care Medicine, 9, 3, pp. 313-9
Pediatric Critical Care Medicine, 9, 313-9
Pediatric Critical Care Medicine, 9, 313-9
Contains fulltext : 69467.pdf (Publisher’s version ) (Closed access) OBJECTIVE: This study was undertaken to validate the transpulmonary thermodilution cardiac output measurement (CO(TPTD)) in a controlled newborn animal model under various hemodyn
Autor:
Arno van Heijst, Johannes G. van der Hoeven, Willem P. de Boode, Jeroen C.W. Hopman, S.L.A.G. Vrancken, Kian D. Liem
Publikováno v:
Journal of Clinical Monitoring and Computing, 29, 5, pp. 643-52
Journal of Clinical Monitoring and Computing, 29, 643-52
Journal of Clinical Monitoring and Computing, 29, 643-52
Contains fulltext : 152964.pdf (Publisher’s version ) (Closed access) To analyze changes in cardiac output and hemodynamic volumes using transpulmonary ultrasound dilution (TPUD) in a neonatal animal model under different hemodynamic conditions. 7
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a6d60e00fd327e5732acfc477a992f79
https://hdl.handle.net/2066/152964
https://hdl.handle.net/2066/152964
Publikováno v:
Biology of the Neonate, 89, 35-41
Biology of the Neonate, 89, 1, pp. 35-41
Biology of the Neonate, 89, 1, pp. 35-41
Background: Insufficient cerebral O2 supply leads to cellular energy failure and loss of brain cell function. The relationship between the severity of cellular energy failure due to hemorrhagic hypotension and the loss of electrocortical brain activi
Publikováno v:
Pediatric Research, 57, 3, pp. 358-62
Pediatric Research, 57, 358-62
Pediatric Research, 57, 358-62
Item does not contain fulltext The fetal brain develops rapidly during the last trimester of pregnancy. Therefore, the brain of infants who are born preterm is vulnerable to changes in oxygen and nutrient supply in the neonatal period. The objective