Zobrazeno 1 - 10
of 27
pro vyhledávání: '"Jennifer E. Decker"'
Autor:
Eleanor Haine-Bennett, Hilary B. Bergsieker, Imogen R. Coe, Andrea Koch-Kraft, Eve Langelier, Suzanne Morrison, Katrin Nikoleyczik, Toni Schmader, Olga Trivailo, Sue Twine, Jennifer E. Decker
Publikováno v:
FACETS, Vol 5, Pp 228-233 (2020)
Science and engineering research excellence can be maximized if the selection of researchers is made from 100% of the pool of human talent. This requires policies and approaches that encourage broad sections of society, including women and other unde
Externí odkaz:
https://doaj.org/article/a423231b03f64ce49a52d41ffcc90f79
Autor:
Eve Langelier, Toni Schmader, Olga Trivailo, Andrea Koch-Kraft, Imogen R. Coe, Jennifer E. Decker, Eleanor Haine-Bennett, Katrin Nikoleyczik, Hilary B. Bergsieker, Sue Twine, Suzanne Morrison
Publikováno v:
FACETS, Vol 5, Pp 228-233 (2020)
Science and engineering research excellence can be maximized if the selection of researchers is made from 100% of the pool of human talent. This requires policies and approaches that encourage broad sections of society, including women and other unde
Autor:
Christopher T. Kingston, Stephen A. Wise, Jennifer E. Decker, Stephanie A. Hooker, Lu Yang, András E. Vladár, Michael T. Postek, Charles A. Clifford, Zygmunt J. Jakubek, J.M. Makar, K Bosnick, L Dai, Jeffrey A. Fagan, Ralph E. Sturgeon, Benoit Simard, A. R. Hight Walker, Rolf Zeisler, Elisabeth Mansfield
Publikováno v:
Metrologia. 46:682-692
Harmonized sample pre-treatment is an essential first step in ensuring quality of measurements as regards repeatability, inter-laboratory reproducibility and commutability. The development of standard preparation methods for single-wall carbon nanotu
Publikováno v:
Metrologia. 46:11-18
The Consultative Committee for Length (CCL) has recommended that red (633 nm) unstabilized helium–neon lasers, operating on the 3s2 → 2p4 transition, should be included in the list of standard frequencies for realization of the metre. This paper
Uncertainty of Gauge Block Calibration by Mechanical Comparison: A Worked Example for Like Materials
Publikováno v:
NCSLI Measure. 3:30-42
This paper presents a detailed measurement uncertainty analysis for the calibration of gauge blocks made from like materials using a mechanical comparator consisting of opposing styli and a digital readout. After discussing the influence parameters a
Publikováno v:
Metrologia. 45:223-232
A generalized formalism is presented for linking a Comite International de Poids et Mesures (CIPM) key comparison (KC) with similar regional KCs. The mechanism proposed provides a straightforward and practical means for reporting on the equivalence o
Autor:
A.G. Steele, Jennifer E. Decker
Publikováno v:
Nanotechnology Standards ISBN: 9781441978523
Nanotechnology is generally defined as the study, exploitation and/or manipulation of matter with size range from approximately 1 to 100 nm. The focus of nanotechnology is largely on the new and novel properties and/or functionalities of traditional
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::4df3fb38a920c0072b642b7774358924
https://doi.org/10.1007/978-1-4419-7853-0_4
https://doi.org/10.1007/978-1-4419-7853-0_4
Measurement of grating pitch by optical diffraction is one of the few methods currently available for establishing traceability to the definition of the meter on the nanoscale; therefore, understanding all aspects of the measurement is imperative for
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ceaea72c278aedd500682c29c9bea589
https://nrc-publications.canada.ca/eng/view/object/?id=1bf37c29-ef8c-49b4-9873-c89e391b150d
https://nrc-publications.canada.ca/eng/view/object/?id=1bf37c29-ef8c-49b4-9873-c89e391b150d
Publikováno v:
Applied optics. 30(15)
We communicate results of the stable operation of a TEA CO(2) oscillator-amplifiers system, producing pulses of 10(14) W/cm(2) at best focus, furnished with a simple provision for retropulse isolation.
A method for the evaluation of international comparison results is demonstrated by consideration of the CCL-K2 key comparison of long gauge block calibration. CCL-K2 is selected for this illustrative example because the comparison measurand is a geom
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2b2dfd439726b2dcec74615dbb6fa33f
https://doi.org/10.1016/j.measurement.2010.03.004
https://doi.org/10.1016/j.measurement.2010.03.004