Shih-Ming Hsu, Chin-Hui Wu, Jeng-Hung Lee, Ya-Ju Hsieh, Chun-Yen Yu, Yi-Jen Liao, Li-Cheng Kuo, Ji-An Liang, David Y C Huang
Publikováno v:
PLoS ONE, Vol 7, Iss 9, p e44528 (2012)
Dose distributions of (192)Ir HDR brachytherapy in phantoms simulating water, bone, lung tissue, water-lung and bone-lung interfaces using the Monte Carlo codes EGS4, FLUKA and MCNP4C are reported. Experiments were designed to gather point dose measu
Externí odkaz:
https://doaj.org/article/c5107e95a6d2482580cd00aa43e5ec25
Publikováno v:
Radiation Physics and Chemistry. 140:361-364
Ir-192 sources are widely used in brachytherapy and the number of treatments is around seven thousand for the use of the high dose rate (HDR) Ir-192 brachytherapy source per year in Taiwan. Due to its physical half-life of 73.8 days, the source shoul
Publikováno v:
Scientific Reports
The aim of this study was to understand the difference between the measured and calculated irradiation attenuations obtained using two algorithms and to identify the influence of couch attenuation on patient dose verification. We performed eight test
Publikováno v:
Medical Physics. 35:2214-2217
We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of Ir 192 high dose rate (HDR). The chamber should be placed at least this distance away from any wall o
Publikováno v:
Radiation Measurements. 39:1-10
This paper describes modifications to an original design, correction factors and uncertainty evaluations for an improved free-air ionization chamber constructed at the Institute of Nuclear Energy Research (INER, Taiwan). In addition, a comparison of
Autor:
Yung Hui Huang, Jeng Hung Lee, Moon Sing Lee, Shih Ming Hsu, Tou-Rong Chen, Shih-Kai Hung, Yi Jen Liao
Publikováno v:
Radiation Measurements. 46:1477-1479
The radiation dosimetric systems have been developed for more than 50 years and are applied in the measurement of clinical and environment radiation dose. However, most of dosimeters can not repeat reading again in single radiation exposure. Accordin
Publikováno v:
Radiation Protection Dosimetry. 146:100-102
This paper describes the establishment by the Institute of Nuclear Energy Research (INER, Taiwan) of the reference air kerma rate (RAKR) calibration standard for measurement of high-dose rate (HDR) (192)Ir brachytherapy source strength. A bilateral c
Autor:
Jeng Hung Lee, Moon Sing Lee, Yung Hui Huang, Hsi Wen Yang, Chun Yen Yu, Shih Ming Hsu, Shick Kai Hung, Yi Jen Liao
Publikováno v:
Radiation Measurements. 45:553-555
Thermoluminescent dosimeters are widely applied in the measurement of radiation dose. Since the luminescent centers are not lost during the reading process, radiophotoluminescent glass dosimeters (RPLGDs) can be repeatedly readout. The aims of this s
Autor:
Jeng Hung Lee, Chun Yen Yu, Ya-Ju Hsieh, Yi Jen Liao, Chin Hui Wu, Shih Ming Hsu, David Y.C. Huang, Li Cheng Kuo, Ji An Liang
Publikováno v:
PLoS ONE
PLoS ONE, Vol 7, Iss 9, p e44528 (2012)
PLoS ONE, Vol 7, Iss 9, p e44528 (2012)
Dose distributions of (192)Ir HDR brachytherapy in phantoms simulating water, bone, lung tissue, water-lung and bone-lung interfaces using the Monte Carlo codes EGS4, FLUKA and MCNP4C are reported. Experiments were designed to gather point dose measu
Autor:
Shawn S. H. Hsu, Ying-Zong Juang, Yin-Cheng Chang, Shuw-Guann Lin, Da-Chiang Chang, Jeng-Hung Lee
Publikováno v:
2011 IEEE 20th Conference on Electrical Performance of Electronic Packaging and Systems.
An extracting methodology is proposed to characterize the performance of interconnect. This work successfully extracts the interconnect by using transmission matrix (T-matrix) for calculation. This method exhibits its validity without frequency limit