Publikováno v:
Biosensors and Bioelectronics. 15:417-421
A new optical design uses a liquid crystal pixel array (LCPA) to discriminate multiple fluorescence signals on a two-dimensional biosensor array. The LCPA can selectively control the transmission of fluorescence generated from multiple biosensing ele
Publikováno v:
Environmental Science & Technology. 34:704-708
Two primary explosives involved in groundwater contamination, 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), were detected on-site at low ppb levels with a semiautomated fiber optic biosensor. Validation of the Analyte
Publikováno v:
Applied Spectroscopy. 52:96-100
We report on the behavior of monoclonal 4-4-20 mouse anti-fluorescein antibodies sequestered within aerosol-OT (AOT) reverse micelles formed in liquid n-heptane as a function of water loading ( R). Our data suggest that the fluorescein binding site s
Publikováno v:
Applied Spectroscopy Reviews. 32:1-43
It is well-known that the behavior of molecules at interfaces is of critical importance in areas ranging from energy conversion, energy transfer, and chromatography to catalysis and chemical sensing. In this Review we focus on the use of nanosecond a
Publikováno v:
Analytical Chemistry. 66:2433-2440
A new technique that we call phase-resolved evanescent wave induced fluorescence (PREWIF) is introduced and is shown to be useful for studying heterogeneous interfaces under ambient conditions. PREWIF is based on the traditional interfacial selectivi
Autor:
Jeffrey S. Lundgren, Frank V. Bright
Publikováno v:
Analytical chemistry. 68(19)
We report the analytical figures of merit for the first biosensor for ionic surfactant quantification. The biosensor consists of a silanized silica optical fiber, onto which acrylodan-labeled bovine serum albumin (BSA-Ac) is immobilized. Recent work
Publikováno v:
Electroanalysis. 5:289-294
Gold macrodisk, microdisk, and microband electrodes are compared for the anodic stripping voltammetry of Se(IV). All of these electrodes show a stripping peak at 0.79 V with a width at half height of 80–90 mV. The linear dynamic range, limit of det
Publikováno v:
Analytical chemistry. 71(3)
The static and dynamical behavior of a fluorescently labeled mutant of the Escherichia coli periplasmic phosphate binding protein (PBP) was investigated through steady-state and time-resolved fluorescence spectroscopy. As a means of developing a bior
Publikováno v:
Analytical chemistry. 67(20)
We investigate the effects of hydration on acrylodan-labeled bovine and human serum albumin (BSA-Ac and HSA-Ac) in aerosol-OT (AOT) reverse micelles solubilized in n-heptane. Time-resolved fluorescence intensity decay experiments reveal a dipolar rel