Zobrazeno 1 - 10
of 25
pro vyhledávání: '"Janire Saez"'
Autor:
Chiara Barberio, Janire Saez, Aimee Withers, Malavika Nair, Francesco Tamagnini, Roisin M. Owens
Publikováno v:
Advanced healthcare materials. 11(20)
3D cell culture formats more closely resemble tissue architecture complexity than 2D systems, which are lacking most of the cell-cell and cell-microenvironment interactions of the in vivo milieu. Scaffold-based systems integrating natural biomaterial
Autor:
Achilleas Savva, Janire Saez, Chiara Barberio, Zixuan Lu, Chrysanthi-Maria Moysidou, Konstantinos Kallitsis, Aimee Withers, Charalampos Pitsalidis, Róisín M. Owens
Publikováno v:
bioRxiv
Three-dimensional in vitro stem cell models has enabled a fundamental understanding of cues that direct stem cell fate and be used to develop novel stem cell treatments. While sophisticated 3D tissues can be generated, technology that can accurately
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5710c6a87c6e60283c2c2b26b6e28ad0
https://doi.org/10.1101/2022.03.30.486455
https://doi.org/10.1101/2022.03.30.486455
Publikováno v:
Engineering Biomaterials for Neural Applications ISBN: 9783031114083
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7149820926a1e17b2d88929cfb3d6c2c
https://doi.org/10.1007/978-3-031-11409-0_1
https://doi.org/10.1007/978-3-031-11409-0_1
Autor:
Raquel Catalan-Carrio, Janire Saez, Luis Ángel Fernández Cuadrado, Gorka Arana, Lourdes Basabe-Desmonts, Fernando Benito-Lopez
Publikováno v:
Addi. Archivo Digital para la Docencia y la Investigación
instname
instname
[EN] Nowadays, miniaturization and portability are crucial characteristics that need to be considered for the development of water monitoring systems. In particular, the use of handheld technology, including microfluidics, is exponentially expanding
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d1a74803421c6d073ef76eeefab072f1
http://hdl.handle.net/10810/56687
http://hdl.handle.net/10810/56687
Autor:
Charalampos, Pitsalidis, Anna-Maria, Pappa, Alexander J, Boys, Ying, Fu, Chrysanthi-Maria, Moysidou, Douglas, van Niekerk, Janire, Saez, Achilleas, Savva, Donata, Iandolo, Róisín M, Owens
Publikováno v:
Chemical reviews. 122(4)
Bioelectronics have made strides in improving clinical diagnostics and precision medicine. The potential of bioelectronics for bidirectional interfacing with biology through continuous, label-free monitoring on one side and precise control of biologi
Autor:
Lourdes Basabe-Desmonts, Janire Saez, Fernando Benito-Lopez, Maite Garcia-Hernando, Róisín M. Owens, Achilleas Savva
Publikováno v:
Addi: Archivo Digital para la Docencia y la Investigación
Universidad del País Vasco
Addi. Archivo Digital para la Docencia y la Investigación
instname
Biosensors and Bioelectronics
Universidad del País Vasco
Addi. Archivo Digital para la Docencia y la Investigación
instname
Biosensors and Bioelectronics
Non-invasive collection of target cells is crucial for research in biology and medicine. In this work, we combine a thermo-responsive material, poly(N-isopropylacrylamide), with an electroactive material, poly(3,4-ethylene-dioxythiopene):poly(styrene
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ed733be499468b1f36841fe3ad4f0c9b
http://hdl.handle.net/10810/51939
http://hdl.handle.net/10810/51939
Autor:
Fernando Benito-Lopez, Thomas Carzaniga, Janire Saez, Marco Buscaglia, Deborah Abati, Roberta Lanfranco
Publikováno v:
Addi. Archivo Digital para la Docencia y la Investigación
instname
Addi: Archivo Digital para la Docencia y la Investigación
Universidad del País Vasco
instname
Addi: Archivo Digital para la Docencia y la Investigación
Universidad del País Vasco
A microfluidic, label-free optical sensor for water pollutants, which is based on a packed micro-column of microspheres with refractive index similar to that of water, is presented. The perfluoropolyether microspheres are synthetized by membrane emul
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::9aa732a35b3ef91674e9313eee412cd5
http://hdl.handle.net/10810/51054
http://hdl.handle.net/10810/51054
Autor:
Janire Saez, Fernando Benito-Lopez, Raquel Catalan-Carrio, Lourdes Basabe-Desmonts, Róisín M. Owens
Publikováno v:
Addi. Archivo Digital para la Docencia y la Investigación
instname
Addi: Archivo Digital para la Docencia y la Investigación
Universidad del País Vasco
instname
Addi: Archivo Digital para la Docencia y la Investigación
Universidad del País Vasco
Water quality monitoring of drinking, waste, continental and seawaters is of great importance to ensure safety and wellbeing for humans, fauna and flora. Researchers are developing robust water monitoring microfluidic devices but, the delivery of a c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::97758b660a0389faf8d719389b2b048e
http://hdl.handle.net/10810/50717
http://hdl.handle.net/10810/50717
Autor:
Janire Saez, Fernando Benito-Lopez, Dermot Diamond, Jeroen ter Schiphorst, Albertus P. H. J. Schenning
Publikováno v:
Lab on a Chip. 18(5):699-709
While the microfluidic device itself may be small, often the equipment required to control fluidics in the chip unit is large e.g. pumps, valves and mixing units, which can severely limit practical use and functional scalability. In addition, compone
Publikováno v:
Advanced Biology
Respiratory diseases and lower respiratory tract infections are among the leading cause of death worldwide and, especially given the recent severe acute respiratory syndrome coronavirus‐2 pandemic, are of high and prevalent socio‐economic importa