Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Jang Lyul Kim"'
Publikováno v:
Nuclear Engineering and Technology, Vol 47, Iss 7, Pp 939-944 (2015)
The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five
Externí odkaz:
https://doaj.org/article/948fc2fc34e44c718a8b917a179074b4
Publikováno v:
Nuclear Engineering and Technology, Vol 46, Iss 2, Pp 273-280 (2014)
The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted
Externí odkaz:
https://doaj.org/article/8e1fb842c8be4413856f3b38957b9af7
Autor:
Byeong Ryong Park, Jae Seok Kim, Jaeryong Yoo, Wi-Ho Ha, Seongjae Jang, Yeong-Rok Kang, HyoJin Kim, Han-Ki Jang, Ki-Tek Han, Jeho Min, Hoon Choi, Jeongin Kim, Jungil Lee, Hyoungtaek Kim, Jang-Lyul Kim
Publikováno v:
Nuclear Engineering and Technology, Vol 52, Iss 10, Pp 2379-2386 (2020)
This paper presents the results of the first intercomparison exercise performed by the Korea retrospective dosimetry (KREDOS) working group using electron paramagnetic resonance (EPR) spectroscopy. The intercomparison employed the alanine dosimeter,
Externí odkaz:
https://doaj.org/article/796e3c55e4f4419a8436abe94c018408
Autor:
Han-Ki Jang, Jae-Seok Kim, Jaeryong Yoo, Jeong-In Kim, Jeho Min, Wi-Ho Ha, Jungil Lee, Yeong-Rok Kang, Seongjae Jang, Hyo-Jin Kim, Jang-Lyul Kim, Ki-Tek Han, Byeong Ryong Park, Hoon Choi, Hyoungtaek Kim
Publikováno v:
Nuclear Engineering and Technology, Vol 52, Iss 10, Pp 2379-2386 (2020)
This paper presents the results of the first intercomparison exercise performed by the Korea retrospective dosimetry (KREDOS) working group using electron paramagnetic resonance (EPR) spectroscopy. The intercomparison employed the alanine dosimeter,
Autor:
Hyoungtaek Kim, Min Chae Kim, Sang In Kim, Seung Kyu Lee, Jang-Lyul Kim, Jung-Il Lee, Insu Chang
Publikováno v:
Journal of Radiation Protection and Research. 44:72-78
Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system,
Publikováno v:
Radiation Measurements. 122:53-56
Forty mobile phones using active-matrix organic light-emitting diode (AMOLED) display glasses were tested as emergency dosimeters. The target material was a substrate glass for AMOLED layers located under a cover glass. The measured thermoluminescenc
Publikováno v:
Journal of Radiation Protection and Research. 43:160-169
Publikováno v:
Radiation Measurements. 118:20-25
Phototransferred thermoluminescence (PTTL) characteristics of LiF:Mg,Cu,Si, developed by the Korea Atomic Energy Research Institute, are presented as part of a simple and reliable method for dose re-evaluation that is compatible with routine personal
Autor:
Jungil Lee, Jang-Lyul Kim, Insu Chang, Bong-Hwan Kim, Seung Kyu Lee, Sang In Kim, Hyoungtaek Kim, Min Chae Kim
Publikováno v:
Radiation protection dosimetry. 187(3)
There is no standardised on-site calibration system for performance testing and calibration of neutron area monitors although there is a mobile irradiation device as like a neutron howitzer. For this reason, neutron area monitors, which legally and p
Autor:
Jungil Lee, K.S. Chung, Michael Discher, Clemens Woda, Sangyeob Lim, Insu Chang, Seung Kyu Lee, Hyoungtaek Kim, Min Chae Kim, Jang Lyul Kim
Publikováno v:
Radiation Measurements. 134:106321
The thermoluminescence of different chip cards was measured and analyzed for emergency dosimetry. Three SIM cards that are commonly found in mobile communication providers in South Korea and three smart IC cards that can be purchased online were used