Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Jan-Erik Grindborg"'
Publikováno v:
Medical Physics. 38:5539-5550
Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in ...
Autor:
Emelie Adolfsson, Eva Lund, Jan-Erik Grindborg, Håkan Gustafsson, Åsa Carlsson Tedgren, Gudrun Alm Carlsson
Publikováno v:
Medical Physics. 37:4946-4959
PURPOSE:To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at 60Co energies. High energy ...
Publikováno v:
Medical Physics. 37:2777-2786
Purpose: To compare a Monte Carlo (MC) characterization of a Co-60 unit at the Swedish Secondary Standard Dosimetry Laboratory (SSDL) with the results of both measurements and literature with the a ...
Publikováno v:
Radiotherapy and Oncology. 86:126-130
Background and purpose: To investigate the status of source strength determination in terms of reference air kerma rate (RAKR) for HDR and PDR 192Ir brachytherapy in Sweden. Materials and methods: RAKR was determined in each of the 14 Swedish afterlo
Autor:
J. E. Lillhök, G. Alm Carlsson, Irena Gudowska, Jonas Söderberg, Hooshang Nikjoo, Lennart Lindborg, Jan-Erik Grindborg
Publikováno v:
Radiation Protection Dosimetry. 126:463-466
A comparison of calculated and measured values of the dose mean lineal energy (yD) for the former neutron therapy beam at Louvain-la-Neuve is reported. The measurements were made with wall-less tissue-equivalent proportional counters using the varian
Publikováno v:
Physics in medicine and biology. 60(21)
The relative standard deviation, σr,D, of calculated multi-event distributions of specific energy for (60)Co ϒ rays was reported by the authors F Villegas, N Tilly and A Ahnesjo (Phys. Med. Biol. 58 6149-62). The calculations were made with an upgr
The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least +/-
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::232e0872d52ea7146189ae4713d0857e
http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-112993
http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-112993
Publikováno v:
Physics in Medicine and Biology. 46:729-740
The long-term sensitivity and calibration stability of liquid ionization chambers (LICs) has been studied at a local and a secondary standards dosimetry laboratory over a period of 3 years. The chambers were transported several times by mail between
Publikováno v:
Medical Physics. 25:900-907
Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies
Autor:
Antti Kosunen, Hans Bjerke, Petri Sipilä, Åsa Carlsson Tedgren, Linda Persson, Per-Otto Hetland, Taran Paulsen Hellebust, Jan-Erik Grindborg
Publikováno v:
Brachytherapy. 13(4)
According to the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism used for dose calculation in brachytherapy treatment planning systems, the absolute level of absorbed dose is determined through coupling with the mea