Zobrazeno 1 - 10
of 79
pro vyhledávání: '"James M. Tinjum"'
Publikováno v:
Environmental Geotechnics. :1-15
A mining tail cover system for controlling toxic substances (e.g. chromium (VI) (Cr6+)) in chromium ore processing residue (COPR) requires unsaturated transport modelling with inputs of water retention curves (WRCs) to evaluate the system. This study
Autor:
Chris Korose, Andrew J. Stumpf, Lauren Thomas, Yongqi Lu, Wenfeng Fu, Jeff Urlaub, Scott M. Frailey, Franklin H. Holcomb, Kevin Fisher, Zhaowang Lin, Timothy D. Stark, Yu-Feng Lin, W. John Nelson, Austyn Vance, James R. Damico, Roland T. Okwen, James Kirksey, Scott D. Elrick, Damon Garner, Jiale Lin, Chuck Hammock, Fang Yang, James M. Tinjum, Hafiz H. Salih, Ray McKaskle
U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Geothermal Technologies Office Award Number DE-EE0008106
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::94c759c9b3f50d220066bf63114367e4
https://doi.org/10.2172/1821557
https://doi.org/10.2172/1821557
Publikováno v:
Journal of Hazardous, Toxic, and Radioactive Waste. 25
Leaching characteristics of chromium ore processing residue (COPR) for the long term (simulating a 20-year leaching scenario) were investigated using laboratory flow-through column testing...
Publikováno v:
Journal of environmental management. 280
This study evaluated the transport mechanisms and emission rates of landfill gas (LFG) from 200- (vegetated with short grass), 300- (vegetated with short grass), and 450-mm-thick (non-vegetated) interim cover soils within a municipal solid waste land
Autor:
Hyunjun Oh, James M. Tinjum
Publikováno v:
Geo-Congress 2020.
Autor:
Hyunjun Oh, James M. Tinjum
Publikováno v:
E3S Web of Conferences, Vol 205, p 07004 (2020)
This study evaluates a two-step, cross-sectional approach for designing shallow, unsaturated, horizontal, ground-based heat exchangers (GHXs). Numerical modeling was conducted for coupled heat and moisture transfer around GHXs under transient climato
Autor:
James M. Tinjum, Hyunjun Oh
Publikováno v:
E3S Web of Conferences, Vol 205, p 07005 (2020)
High fluid temperatures in ground-based heat exchangers (GHXs) during the cooling season may result in a decrease in thermal conductivity of adjacent backfill (λbackfill), potentially causing degradation in the performance efficiency of the GHX syst
Publikováno v:
Geothermics. 76:116-124
A fiber optic distributed thermal response test (DTRT) conducted in well-documented heterogeneous geology is combined with laboratory thermophysical measurements of cores and novel data analysis techniques to provide a detailed description of variabi
Publikováno v:
Geotextiles and Geomembranes. 46:426-435
The impact of α and β radiation on antioxidant depletion in smooth high-density polyethylene (HDPE) geomembranes (GMs) is described. Smooth HDPE GMs having different thickness (0.04-mm, 0.1-mm, 0.2-mm) were created by mechanically pulverizing secti
Publikováno v:
IEEE Sensors Journal. 18:2342-2352
Distributed Temperature Sensing (DTS) is a technique that uses the interaction of laser pulses with silica to continuously sense temperature along the length of fiber-optic cables. The temporal and spatial resolution of DTS makes it an excellent tech