Zobrazeno 1 - 10
of 114
pro vyhledávání: '"James C.H. Chu"'
Autor:
H. Thompson Heaton, Michael R. Ringor, Robert A. Cormack, Peter J. Biggs, Tina L. Pike, Bruce R. Thomadsen, Habib Safigholi, Christopher Stacey, Frank Weigand, Jonathan N. Law, Jessica R. Hiatt, Sujatha Pai, Mark J. Rivard, Wenzheng Feng, Zoubir Ouhib, Randall W. Holt, Timothy J. Waldron, James C.H. Chu, Gene A. Cardarelli, Jeffery P. Limmer, Sushakumari Pillai, Barrett S. Caldwell
Publikováno v:
Medical physicsReferences. 47(4)
PURPOSE The purpose of this study was to provide guidance on quality management for electronic brachytherapy. MATERIALS AND METHODS The task group used the risk-assessment approach of Task Group 100 of the American Association of Physicists in Medici
Autor:
James C.H. Chu, T Halabi, Michael C. Kirk, Damian Bernard, Hsiao-Ming Lu, Y Lei, Russell J. Hamilton, J Driewer
Publikováno v:
Medical Physics. 43:4966-4972
Purpose: To identify policy and system related weaknesses in treatment planning and plan check work-flows. Methods: The authors’ web deployed plan check automation solution, PlanCheck, which works with all major planning and record and verify syste
Autor:
Alistair Templeton, Julius V. Turian, Kevin C. Jones, John Strologas, Gage Redler, Gizem Cifter, James C.H. Chu, Damian Bernard
Publikováno v:
Phys Med Biol
By collecting photons scattered out of the therapy beam, scatter imaging creates images of the treated volume. Two phantoms were used to assess the possible application of scatter imaging for markerless tracking of lung tumors during stereotactic bod
Publikováno v:
Decision Analytics and Optimization in Disease Prevention and Treatment
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::66c366b84b12dd62bd7be6bbf4e25979
https://doi.org/10.1002/9781118960158.ch12
https://doi.org/10.1002/9781118960158.ch12
Publikováno v:
Journal of Applied Clinical Medical Physics
Three‐dimensional measurement arrays are an efficient means of acquiring a distribution of data for patient plan delivery QA. However, the tie between plan integrity and traditional gamma‐based analysis of these data are not clear. This study exp
Autor:
H Zhen, Y Liao, Damian Bernard, Gage Redler, Katherine L. Griem, Julius V. Turian, James C.H. Chu, Alistair Templeton
Publikováno v:
Brachytherapy. 17(2)
Purpose The Xoft Axxent Electronic Brachytherapy System (Xoft, Inc., San Jose, CA) is a viable option for intraoperative radiation therapy (IORT) treatment of early-stage breast cancer. The low-energy (50-kVp) X-ray source simplifies shielding and in
Autor:
Gage Redler, Damian Bernard, James C.H. Chu, Kevin C. Jones, Julius V. Turian, Alistair Templeton
Publikováno v:
Medical physics. 45(3)
PURPOSE Lung stereotactic body radiation therapy (SBRT) requires delivering large radiation doses with millimeter accuracy, making image guidance essential. An approach to forming images of patient anatomy from Compton-scattered photons during lung S
Publikováno v:
Brachytherapy. 17:S17-S18
Publikováno v:
Radiotherapy and Oncology. 133:S98
Publikováno v:
Interfaces. 43:462-476
Cervical cancer has a high mortality rate (approximately 35 percent) in the United States and is difficult to treat successfully. One promising treatment is high-dose-rate brachytherapy, which entails delivering high-dose radiation to the tumor via t