Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Jaap Brink"'
Autor:
Man Wei Tam, Jaap Brink
Publikováno v:
Journal of Structural Biology. 116:144-149
We have developed two software packages for the processing of electron diffraction patterns acquired on a slow-scan CCD camera. Automated indexing and processing of these electron diffraction patterns is possible using a program called AUTO. To obtai
Autor:
Jaap Brink, Wah Chiu
Publikováno v:
Journal of Structural Biology. 113:23-34
A Gatan 1024 × 1024 slow-scan charge-coupled device (CCD) camera has been interfaced to a JEOL4000EX electron cryomicroscope and explored for its usefulness in the electron crystallographic analysis of thin, glucose-embedded crystals of crotoxin com
Publikováno v:
Ultramicroscopy. 52(2)
Electron energy loss spectroscopy and dark-field imaging in a scanning transmission electrton microscope were used to determine the thickness of glucose-embedded crotoxin complex crystals. The results demonstrate the feasibility of identifying protei
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 53:8-9
In protein electron crystallography, high resolution amplitudes and phases are required for a 3D reconstruction of a protein in which one can trace the Cα-backbone. Recording of these amplitudes and phases has so far been done on photographic film.
Autor:
Jaap Brink, Wah Chiu
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 52:104-105
Crotoxin complex is the principal neurotoxin of the South American rattlesnake, Crotalus durissus terrificus and has a molecular weight of 24 kDa. The protein is a heterodimer with subunit A assigneda chaperone function. Subunit B carries the lethal
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 52:98-99
In protein electron crystallography, both low dose electron diffraction patterns and images are needed to provide accurate amplitudes and phases respectively for a 3-dimensional reconstruction. We have demonstrated that the Gatan 1024x1024 model 679
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 52:118-119
There is an ever present need in electron microscopy of biological specimens to improve the quality of the recorded data to approach the atomic resolution capability of the modem instruments. The method adopted which has yielded the only significant
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 51:686-687
In three-dimensional structure determination of macromolccules by electron crystallography it is necessary to combine diffraction patterns and images recorded at various tilt angles from different crystals. In order to merge these data sets successfu
Publikováno v:
Proceedings, annual meeting, Electron Microscopy Society of America. 50:1054-1055
Protein electron crystallography can provide a reconstruction detailed enough for the polypeptide chain of a membrane protein to be traced (1). However, there remain a number of technical problems associated with this technique that must be overcome
Publikováno v:
Ultramicroscopy. 27:91-99
Two-dimensional crystals of bovine NADH: ubiquinone oxidoreductase fragments were studied by cryo-electron microscopy and computer image analysis at two focus settings. The lattice parameters of the crystals were determined as a =14.5±0.2 nm , b =14