Zobrazeno 1 - 10
of 258
pro vyhledávání: '"J.T. Rhee"'
Publikováno v:
Applied Radiation and Isotopes. 110:64-69
A useful approach for the enhancement of thermal neutrons detection has been reported here. This technique, based on the angular and micro pattern effects, has been developed and applied to the boron-coated ((10)B) Gas Electron multiplier (GEM) detec
Publikováno v:
Measurement. 60:71-77
In the current work, we demonstrate the possibility of using the FLAIR (an advanced user friendly interface) that can be employed for building the radiation simulator via inserting the basic parameters in it. Generally, the FLAIR interface is utilize
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 732:233-236
In this work, we demonstrate the feasibility and characteristics of a single-gap parallel plate avalanche counter (PPAC) as a low energy neutron detector, based on Gd-converter coating. Upon falling on the Gd-converter surface, the incident low energ
Publikováno v:
Radiation Measurements. 45:840-843
The Resistive Plate Chamber (RPC) has been developed in many application areas ever since its introduction, from high energy physics experiments to positron emission tomography. Such detectors can be coated with a Gd layer that enables them to detect
Autor:
Hye-Sun Kim, C. Kim, H. B. Rhee, K. S. Sim, S.Y. Bahk, Mihee Jo, Sung Keun Park, Ye-Seul Kim, J.T. Rhee, S.J. Lee, S.J. Hong, Soon-Kwon Nam, K. S. Lee, Y. J. Kim, R.J. Hu, Byung-Sik Hong
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 602:771-774
A systematic study with a series of irradiation tests was performed for the forward resistive plate chambers (RPCs) of the Compact Muon Solenoid (CMS) in the Large Hadron Collider (LHC) experiment. Small double-gap RPCs were manufactured and tested b
Publikováno v:
Radiation Measurements. 43:1554-1557
Results about single gap Resistive Plate Chambers' (RPCs) sensitivity to neutrons obtained with a Monte Carlo code based on GEANT4 are reported. The neutron sensitivity has been studied in the energy range between 100 eV and 1.0 GeV. The results from
Publikováno v:
Pramana. 71:559-572
This article reports a comparative study of the phase separation process in a polymer-dispersed liquid crystal, based on a Metropolis Monte Carlo simulation study of three lattice systems. We propose a model for the different processes occurring in t
Publikováno v:
Radiation Measurements. 42:1545-1551
Resistive plate chambers (RPCs) have been chosen as a part of the muon trigger detectors in the CMS experiment. They are used both in the endcaps and in the barrel regions, and they have to work in an extreme radiation background. Test of glass-RPC d
Publikováno v:
Radiation Measurements. 42:1368-1372
In this work we describe the simulation response of float-glass resistive plate chambers (RPCs) exposed to gamma rays in the energy range 0.1–100 MeV. In the present study of RPC setup, float-glass electrodes are utilized instead of bakelite plates
Publikováno v:
Pramana. 69:377-386
In this study the performance of double gap RPC has been tested by GEANT4 Monte Carlo simulation code. The detector response calculations taken as a function of the neutron energy in the range of 0.01 eV-1 GeV have been simulated through RPC set-up.