Zobrazeno 1 - 10
of 11
pro vyhledávání: '"J. W. M. Van Os"'
Publikováno v:
Chemical Physics Letters. 280:31-39
An adiabatic homonuclear polarization-transfer scheme is introduced. It involves an adiabatic passage through the rotational-resonance condition (APRR) experimentally realized by a ramp of the MAS speed. The APRR experiment is demonstrated to lead to
Publikováno v:
Chemical Physics Letters, 376, 338-345
Chemical Physics Letters, 376, 3-4, pp. 338-345
Chemical Physics Letters, 376, 3-4, pp. 338-345
Strategies for successful solid-state NMR experiments in high-field Bitter and hybrid magnets are discussed and implemented on an older generation 24 T system. In general, the stability and homogeneity of this type of magnets do not meet the requirem
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a7273edd80e944c8d17dccbdc914cb48
http://hdl.handle.net/2066/76631
http://hdl.handle.net/2066/76631
Publikováno v:
International Journal of Modern Physics : B, Condensed Matter Physics, Statistical Physics, Applied Physics, 16, 22, pp. 3405-3405
International Journal of Modern Physics : B, Condensed Matter Physics, Statistical Physics, Applied Physics, 16, 3405-3405
International Journal of Modern Physics : B, Condensed Matter Physics, Statistical Physics, Applied Physics, 16, 3405-3405
As an exploratory study for NMR experiments in the future 20 MW Nijmegen high field magnet laboratory, the possibilities of field stabilization and field gradient compensation in a 25 T hybrid magnet in the present installation were evaluated. High f
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fb6d431b902b34948f5cfd66f2cdaa3c
https://hdl.handle.net/2066/76629
https://hdl.handle.net/2066/76629
Publikováno v:
Review of Scientific Instruments. 62:1285-1287
An instrument is described that allows fast phase‐continuous frequency switching and modulation. The instrument is designed to switch to a new frequency for a period of time or to a series of frequencies, and then switch back to the original freque
Publikováno v:
Review of Scientific Instruments, 64, 11, pp. 3340-3341
Review of Scientific Instruments, 64, 3340-3341
Review of Scientific Instruments, 64, 3340-3341
A device is described that enables time control of many external devices on any nuclear magnetic resonance spectrometer even if it has only one control output available for switching external appliances. Furthermore, it allows activation of extra dev
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::665cbc1bf57242d59d9828ec3437d2ef
https://hdl.handle.net/2066/76580
https://hdl.handle.net/2066/76580
Publikováno v:
Solid State NMR of Polymers ISBN: 9781489924766
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5162d2168bb5308fd423de54665f30ac
https://doi.org/10.1007/978-1-4899-2474-2_22
https://doi.org/10.1007/978-1-4899-2474-2_22
Publikováno v:
Journal of Magnetic Resonance (1969). 76:543-547
It is demonstrated that NMR images may be obtained from solids rotating at the magic angle. This approach leads to line narrowing in favorable samples and is easily implemented. In very rigid systems it is suggested that imaging be performed with a c
Autor:
Wiebren S. Veeman, J. W. M. van Os
Publikováno v:
Review of Scientific Instruments. 50:445-449
A programmable pulse generator is described for NMR spectrometers. The pulse generator can operate either in a single cycle mode where up to 16 pulses can be given sequentially or, in the double cycle mode, a programmable number (/=15) of these pulse
Publikováno v:
Chemical Physics Letters. 143:467-470
The first two-dimensional 1H NMR image of a solid whose linewidth is not narrowed by motional averaging is presented. The image of a polyethylene phantom was acquired with line narrowing by multiple-pulse coherent averaging of the homonuclear dipolar
Publikováno v:
Journal of Magnetic Resonance (1969). 51:56-66
It is shown experimentally and by calculations, using average Hamiltonian theory, that the decoupling efficiency of the composite decoupling schemes MLEV-4 and MLEV-16, introduced by Levitt, Freeman, and Frenkiel, can be improved by inserting delays