Zobrazeno 1 - 10
of 32
pro vyhledávání: '"J. W. E. van Dijk"'
Autor:
José do Patrocínio Hora Alves, B. Vekic, F. Rossi, P. J. Gilvin, J. W. E. van Dijk, M. Lehtinen, C. Cherestes
Publikováno v:
Radiation Measurements. 71:434-437
EURADOS Working Group 2 (WG2) on Harmonization of Individual Monitoring is a network of individual monitoring services (IMSs) that aims to promote quality, technical excellence and good practice in European Member States. To help to improve quality,
Among the activities of EURADOS Working Group 2 formed by experts from several European countries is the harmonisation of individual monitoring as part of radiation protection of occupationally exposed persons. Here, we provide information about ther
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a66f6ffb3e62b7723f11b61eaf4491e9
http://doc.rero.ch/record/299393/files/nci538.pdf
http://doc.rero.ch/record/299393/files/nci538.pdf
Publikováno v:
Radiation Protection Dosimetry. 144:202-206
During readout, the signal of the TLD is occasionally polluted with spurious signals. These most often take the shape of a spike on the glow curve. Often these spikes are only a few milliseconds wide but can have a height that significantly influence
Autor:
V. Kamenopoulou, David Bartlett, E. Fantuzzi, José do Patrocínio Hora Alves, J. W. E. van Dijk, P. Ambrosi, L. Currivan
Publikováno v:
Radiation Protection Dosimetry. 144:17-25
The purpose of the European Commission technical recommendations (TR) for monitoring individuals occupationally exposed to external radiation is to provide guidance on those aspects of the implementation of the European Union Parliament and Council D
Publikováno v:
Bulletin des Sociétés Chimiques Belges. 95:337-342
On the basis of the composition of the mineral in bone and the saturation level of blood plasma with respect to the slightly soluble calcium phosphates it is shown that normal tissue fluids are not supersaturated with whole bone but with the minerals
Autor:
P. de Jong, J. W. E. van Dijk
Publikováno v:
Radiation Protection Dosimetry. 132:381-389
In this study, a model to determine the indoor absorbed dose rate in air due to building materials is applied to a representative set of 1336 Dutch dwellings of which the areas occupied by the various kinds of building material are well documented. U
Autor:
J. W. E. van Dijk
Publikováno v:
Radiation Protection Dosimetry. 125:387-394
In the 1990 Recommendations of the ICRP it is stated that an uncertainty in a dose measured with a personal dosemeter under workplace conditions of a factor 1.5 in either direction 'will not be unusual'. In many documents similar to the EU Technical
Autor:
J. W. E. van Dijk
Publikováno v:
Radiation Protection Dosimetry. 123:318-322
Maintaining the integrity of the databases is one of the important aspects of quality assurance at individual monitoring services and national dose registers. This paper presents a method for finding and preventing the occurrence of duplicate entries
Autor:
J. W. E. van Dijk
Publikováno v:
Radiation Protection Dosimetry. 120:250-258
Based on recommendations of the International Commission on Radiological Protection, recommendations and requirements on the performance of dosimetric systems and individual monitoring services have been formulated in national and international stand
Autor:
J. W. E. van Dijk
Publikováno v:
Radiation Protection Dosimetry. 119:332-338
Analysing thermoluminescence glow curves involves the solving of a system of non-linear equations. These equations are either differential equations that must be solved numerically or functional approximations for their solution. The current paper pr