Publikováno v:
Applied Radiation and Isotopes. 49:1207-1211
Until recently, we have used indirect methods (modelling with solid sources, theoretical calculation, etc.) for the calibration of equipment for activity concentration measurement of noble gases. After producing our gas certified reference source (CR
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 369:463-466
The activity of 85Kr gas in a glass ampoule was measured by means of a solid certified reference source (CRS) of 85Sr and a HPGe gamma-spectrometer. A Marinelli beaker of 101 was filled with 85Kr gas and closed. The activity of the reference gas was
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 369:359-362
A short account is given of the liquid scintillation coincidence system developed at OMH for the standardization of pure-beta emitting and electron-capture radionuclides. Our experience of direct activity concentration measurements is outlined for 14
Publikováno v:
Applied Radiation and Isotopes. 49:1459-1461
Pursuant to the Hungarian Law on Legal Metrology, activity measurements in nuclear medicine can be made by verified measuring instruments only. OMH has carried out this legal metrological task of verification for more than 15 years. This paper outlin
Autor:
Matyas Koltai, P. Megyeri, Csongor S. Ábrahám, Zoltán Szilvássy, József Kovács, Sándor Pintér, Ferenc Bari, Mária A. Deli, P. Németh, Péter Temesvári, Laszlo Nemeth, B. Gellén, Miklós Vecsernyés, J. Vágvölgyi
Publikováno v:
Pediatric surgery international. 19(5)
Necrotizing enterocolitis (NEC) is the most common acquired gastrointestinal emergency in neonates. We have developed an animal model of NEC in asphyxiated newborn pigs and investigated the effects of asphyxia on blood flow in superior mesenteric art
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 18:98-102
A versatile TLD reader built from integrated circuits is described. The changeable heating drawers make it possible to evaluate a wide variety of TL materials with high precision. The reader's high sensitivity makes it especially useful for environme
Publikováno v:
Advances in Space Research. 1:61-66
A small, portable, vibration and shock resistant thermoluminescent dosimeter system was developed to measure cosmic radiation dose on board a spacecraft. The system consists of a small battery-operated reader and a special bulb dosimeter. Doses from
Autor:
Á. Szörényi, J. Vágvölgyi
Publikováno v:
The International Journal of Applied Radiation and Isotopes. 34:1133-1144
In the last two decades various radionuclides have been standardised at the National Office of Measures (OMH) and at the present time OMH offers radioactive standard-reference materials for over 50 radionuclides. Suitable direct and relative methods
Publikováno v:
Radiation Protection Dosimetry. 17:279-281
Publikováno v:
Radiation Protection Dosimetry. 6:100-102