Zobrazeno 1 - 10
of 129
pro vyhledávání: '"J. Okude"'
Autor:
H.K. Mishima, R. Kempf, Hidetoshi Tsukamoto, Yoshichika Iida, S. Katakura, Eiichiro Sugimoto, J. Okude, Yuichi Kurita, K. Kobayashi, Yoshiaki Kiuchi, Makoto Kaneko
Publikováno v:
IEEE transactions on bio-medical engineering. 55(2 Pt 1)
Goldmann applanation tonometry is commonly used for measuring intraocular pressure (IOP) to diagnose glaucoma. However, the measured IOP by conventional applanation tonometry is valid only under the assumption that all subjects have the same structur
Autor:
Geschwind H, J. Okude, Ph. Deleuze, Norihiko Shiiya, Wan F, Jean-Luc Dubois-Randé, D. Loisance, O. Rosenval
Publikováno v:
Temporary Cardiac Assist with an Axial Pump System ISBN: 9783798509061
A new approach in the management of extremely sick patients with unstable myocardial ischaemia selected for coronary angioplasty has been recently proposed (2). It is based on mechanical assistance of the left ventricle, obtained by intra-ventricular
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a73db4e07a80dcc3d97c260b058d9cc5
https://doi.org/10.1007/978-3-662-10284-8_9
https://doi.org/10.1007/978-3-662-10284-8_9
Publikováno v:
ASAIO transactions. 36(3)
Prophylactic implantation of a Hemopump (Johnson and Johnson, Skillman, NJ) has been evaluated in nine patients selected for high risk coronary angioplasty. They were unstable patients, refractory to maximal pharmacology, with indications for revascu
Publikováno v:
Lancet (London, England). 335(8687)
The 'Hemopump', an axial flow pump, when inserted in the left ventricle brings about mechanical unloading of the ventricle, thus reducing the risk of cardiac arrest during coronary angioplasty. In this study eight very ill patients with unstable myoc
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Journal of the American College of Cardiology. 15:A249
Autor:
Smith, Albert A.1 (AUTHOR), Pacull, Emelyne M.1 (AUTHOR), Stecher, Sabrina1 (AUTHOR), Hildebrand, Peter W.1 (AUTHOR), Vogel, Alexander1 (AUTHOR), Huster, Daniel1 (AUTHOR) daniel.huster@medizin.uni-leipzig.de
Publikováno v:
Angewandte Chemie. 8/28/2023, Vol. 135 Issue 35, p1-12. 12p.
Publikováno v:
ASAIO Transactions. 35:442-444
Autor:
P H, Deleuze, Y, Liu, D, Tixier, J, Okude, J, Leandri, M, Gouault, F, Galacteros, J P, Cachera, D, Loisance
Publikováno v:
The International journal of artificial organs. 12(5)
Two comparable groups of four Holstein calves were implanted with different left ventricle assist devices: the Centrimed centrifugal pump (CP) (Sarns Inc.) or the UTAH 85 VAD pneumatic ventricle (University of Utah). Operative procedure, inflow and o
Publikováno v:
Kyobu geka. The Japanese journal of thoracic surgery. 42(5)
This 57-year-old female of MS had been treated by MVR with a 25 mm Omniscience valve on October 26, 1983. She was doing well until November 1984 when she developed general malaise and dyspnea. She was hospitalized again on June 3, 1985. Studies inclu