AIP Conference Proceedings.
The Fermilab Tevatron cryogenic system utilizes high‐speed centrifugal cold compressors, made by Ishikawajima‐Harima Heavy Industries Co. Ltd. (IHI), for high‐energy operations. The compressor is designed to pump 60 g/s of 3.6 K saturated heliu
Autor:
J. N. Makara, M. G. Geynisman
Publikováno v:
AIP Conference Proceedings.
Fermilab’s Tevatron Superconducting Accelerator has begun operations of colliding beams of protons and antiprotons at 980 GeV. This has been accomplished by lowering the operating temperature of the Tevatron magnet system from 4.5K to 3.6K using co
Autor:
M. Geynisman, R. J. Kolar, R. J. Bossert, G. A. Hodge, R. J. Walker, J. N. Makara, T. R. Barnes
Publikováno v:
Advances in Cryogenic Engineering ISBN: 9781461360742
A significant upgrade to the Fermilab Central Helium Liquefier (CHL) facility’s 4000 liters/hour helium system has been made to support the Laboratory’s Tevatron superconducting accelerator. The upgrade includes a second helium liquefier with a r
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::5578065496a0cc67ff8270e0260f4f15
https://doi.org/10.1007/978-1-4615-2522-6_63
https://doi.org/10.1007/978-1-4615-2522-6_63
Publikováno v:
Advances in Cryogenic Engineering ISBN: 9781461292999
Operating experience since the last report, Aug. 1983, is covered. The current mode of supplying liquid helium to the superconducting accelerator ring is explained including a discussion of the interaction of the system with upsets in the ring. The m