Contractile Response to Electrical Stimulation of the Small Intestine in Anesthetized and Awake Dogs
Autor:
Yukihiko Nosé, Gordon Jacobs, Sharon Grundfest-Broniatowski, Anton Moritz, J. Kasick, Laszlo A. Ilyes
Publikováno v:
Artificial Organs. 13:553-557
To test whether small bowel contraction can be induced by electrostimulation similar to in vitro results in anesthetized and awake animals, five dogs had stainless steel electrodes implanted on the serosal surface of the jejunum and ileum. Fifty mill
Publikováno v:
IEEE Transactions on Microwave Theory and Techniques. 50:1561-1570
A new approach for the electro-thermal modeling of LDMOSFETs for power-amplifier design that bypasses pulsed-IVs and pulsed-RF measurements is presented in this paper. The existence of low-frequency dispersion in LDMOSFETs is demonstrated by comparin
Publikováno v:
Cutis. 50(6)
The case of a one-year-old girl with symptomatic zinc deficiency is presented. She had been misdiagnosed as having impetigo and/or candidiasis and had been treated with topical antifungal agents and both oral and topical antibiotic agents without suc
Publikováno v:
Otolaryngology–Head and Neck Surgery. 95:442-449
This article presents a new technique for creation of a model that can be used to study the aerodynamics of the nasal airway. The model is employed to determine parameters used to calculate nasal resistance and modified to compare various types of na
Autor:
Anton Moritz, Gordon Jacobs, J. Kasick, Laszlo A. Ilyes, Yukihiko Nosé, Sharon Grundfest-Broniatowski
Publikováno v:
Langenbecks Archiv f�r Chirurgie. 374:267-271
Voluntary control of the motility of intestinal reservoirs may be used to improve evacuation and continence. In 4 dogs a U-shaped jejunum pouch and in another 4 an ileum pouch was constructed and instrumented with stimulating and EMG electrodes and p
Autor:
A. Moritz, Gordon Jacobs, Laszlo A. Ilyes, Sharon Grundfest-Broniatowski, Yukihiko Nosé, Olsen E, J. Kasick
Publikováno v:
Diseases of the colon and rectum. 31(4)
Ileal reservoirs were constructed in four dogs under general anesthesia and stimulated by means of a constant current generator that produced pulse trains at frequencies between 6 Hz and 1.67 kHz. Stimulation at 6 Hz with 50 ms pulses between amplitu
Autor:
H, Emoto, G, Jacobs, J F, Chen, M, Nasu, T, Oku, M, Ishikawa, N, Uchida, H, Kambic, J, Kasick, H, Harasaki
Publikováno v:
ASAIO transactions. 33(3)
Publikováno v:
ASAIO transactions. 34(3)
The overall purpose of this project was to develop a circulatory assist device that could be used as a bridge to heart transplantation. Although heart muscle damage was one of the disadvantages with the original epicardial assist devices, as long as
Publikováno v:
ASAIO transactions. 34(3)
Pouches constructed from small intestine are used to replace reservoir function after extirpative surgery of the colon. Such pouches empty in an involuntary and uncontrolled fashion. To see whether emptying could be voluntarily controlled, ileal and
Publikováno v:
Transactions - American Society for Artificial Internal Organs. 28
The smooth surface cycled chambers, both Biomer and silicone rubber, developed thick tissue capsules and exhibited persistent active tissue reactions at the diaphragm-capsule interface. Textured surface chambers (dacron velour), both the cycled and c