Zobrazeno 1 - 10
of 20
pro vyhledávání: '"J. J. Jafar"'
Publikováno v:
Surgical neurology. 56(3)
Hearing loss after intracranial and spinal procedures involving cerebrospinal fluid loss is rarely reported in the literature. We report a patient who suffered from delayed hearing loss after cerebrospinal fluid shunting that improved after revising
Autor:
J J, Jafar, P P, Huang
Publikováno v:
Neurosurgery clinics of North America. 9(4)
Carotid cavernous aneurysms are distinct entities. The anatomy of the cavernous sinus region has been well defined, and most spontaneous aneurysms of the cavernous sinus region carry a benign prognosis. Progressively symptomatic, traumatic, or infect
Autor:
J J, Jafar, A R, Rezai
Publikováno v:
Neurosurgery. 34(1)
The majority of intracranial arteriovenous malformations (AVMs) do not require acute surgical intervention. Some patients, however, require emergent surgical treatment because of a profound neurological deterioration from a mass effect. We report 10
Autor:
T. Marotta, A. Setton, Robert H. Rosenwasser, A. Berenstein, H. H. Batjer, J. J. Jafar, D. Samson, P. K. Nelson, P. D. Purdy
Publikováno v:
Journal of Neurosurgery. 79
Publikováno v:
Neurosurgery. 30(1)
Intramedullary spinal cord abscesses are relatively uncommon. We report the first case of an intramedullary spinal cord abscess in a preexisting spinal cord ependymoma. The clinical features and pathogenesis are discussed. Salient features of the man
Publikováno v:
Stroke. 20:664-667
Platelet deposition in the microcirculation may play a role in focal cerebral ischemia. We investigated platelet deposition in selected parts of the cat brain after temporary middle cerebral artery occlusion. Ten anesthesized cats were given autologo
Autor:
D G Spigos, J Machi, R Menoni, J J Jafar, Bernard Sigel, J R Ramos, R M Crowell, Beitler Jc, R A Bernstein
Publikováno v:
Journal of Ultrasound in Medicine. 3:155-161
Imaging ultrasonography was performed during 23 brain and five spinal cord operations with real-time B-mode instruments. Criteria for the utilization of ultrasound at neurosurgical procedures were identified in terms of assistance in the diagnosis or
Publikováno v:
No shinkei geka. Neurological surgery. 12(8)
B-mode real-time ultrasound using 5 or 7.5 MHz transducer has been employed during 21 operations for brain pathology and spinal cord lesions. Ultrasonic scanning was performed at the following operations: 10 brain tumors (4 glioblastomas multiforme,
Publikováno v:
AJNR Am J Neuroradiol
Publikováno v:
Acta radiologica. Supplementum. 369
Three patients with giant aneurysms (2 internal carotid and 1 anterior communicating) were treated by internal carotid occlusion with a detachable balloon. 133Xe regional cerebral blood flow (rCBF) was performed on each patient on admission. Due to l