Zobrazeno 1 - 10
of 18
pro vyhledávání: '"J. J. Baeza Baeza"'
Publikováno v:
International Journal of Chemical Kinetics. 48:449-463
This article critically compares the efficacy of three algorithms, namely Alternating Least-squares Multi Curve Resolution (ALS-MCR), Hard Modeling Alternating Least-squares (HM-ALS), and classical Hard Modeling Multi Curve Resolution (HM-MCR) in fin
Publikováno v:
Analytica Chimica Acta. 381:275-285
The elution behaviour in reversed-phase liquid chromatography (RPLC), with mobile phases containing micelles, can be described according to a distribution pattern among three phases: bulk water, micellar pseudophase and stationary phase. Several mech
Publikováno v:
Analytical Chemistry. 69:3822-3831
A family of models is proposed for the description of skewed chromatographic peaks, based on the modification of the standard deviation of a pure Gaussian peak, by the use of a polynomial function, h(t) = He-(1/2)([t-tR]/[s0+s1(t-tR)+s2(t-tR)2+...])2
Publikováno v:
Chromatographia. 44:145-150
Clenbuterol has been determined in urine by solidphase extraction on a C18 cartridge, diazotization of the eluate with nitrite, coupling of the diazonium ion with 1-(naphthyl)ethylenediamine, and separation of the azo dye formed by HPLC with a C18 co
Publikováno v:
Talanta. 43:1579-1587
The Debye-Hückel semiempirical extended equation is frequently used to calculate activity coefficients of chemical species and equilibrium constants at ionic strengths different from those used in their experimental evaluation. A series expansion of
Autor:
Y. L. Xie, J. J. Baeza-Baeza, J. R. Torres-Lapsió, M. C. García-Alvarez-Coque, G. Ramis-Ramos
Publikováno v:
Chromatographia. 41:435-444
Autor:
E. F. Simó Alfonso, Y.Martin Biosca, Guillermo Ramis-Ramos, J. J. Baeza Baeza, J. S. Esteve Romero
Publikováno v:
Analytica Chimica Acta. 307:145-154
In thermal lens spectrometry (TLS) the intense pump radiation can lead the chromophore to partial optical saturation conditions in which the ground state is depleted and the population of an intermediate excited state increases. A model in which the
Publikováno v:
Analytica Chimica Acta. 296:107-113
A model for thermal lens spectrometry (TLS) in partial optical saturation conditions is developed. The model predicts that optical saturation is approached to a significant degree in many TLS experiments, and that it can be reached to a high degree w
Publikováno v:
Analytica Chimica Acta. 283:785-793
Twol cell configurations involving a rotating bioreactor and a stationary platinum-ring amperometric detector are compared with regard to data produced by continuous-flow and continuous-flow/stopped-flow/continuous-flow operations. In addition to dat
Publikováno v:
Analytical Chemistry. 65:1658-1661
A recently introduced biosensor comprising a rotating bioreactor and a stationary platinum ring amperometric detector (Anal. Chem. 1993, 65, 636-639) has been utilized for the simultaneous determination of fructose and ascorbate. The approach has bee