Opt Express
We have demonstrated the first continuous-scan Electrical Substitution Fourier Transform Spectrometer (ES-FTS), which serves initially as an apparatus for absolute spectral responsivity calibrations of detectors over the wavelength range from 1.5 μm
Publikováno v:
Metrologia
We have developed generalized methods for electrical substitution optical measurements, as well as cryogenic detectors which can be used to implement them. The new methods detailed here enable measurement of arbitrary periodic waveforms by an electri
Autor:
D R Defibaugh, Solomon I. Woods, Adriaan C. Carter, J E Proctor, Timothy M. Jung, J. E. Neira
Publikováno v:
Applied optics. 57(18)
We have designed, fabricated, and measured infrared trap detectors made from arsenic-doped silicon (Si:As) blocked impurity band (BIB) photodetectors. These trap detectors are composed of two detectors in a wedge geometry, with an entrance aperture d
Autor:
D, Smith, M A, Hakeem, P, Parisiades, H E, Maynard-Casely, D, Foster, D, Eden, D J, Bull, A R L, Marshall, A M, Adawi, R, Howie, A, Sapelkin, V V, Brazhkin, J E, Proctor
Publikováno v:
Physical review. E. 96(5-1)
We report experimental evidence for a crossover between a liquidlike state and a gaslike state in fluid methane (CH_{4}). This crossover is observed in all of our experiments, up to a temperature of 397 K, 2.1 times the critical temperature of methan
Publikováno v:
Metrologia. 40:S30-S34
The facility for automated spectroradiometric calibrations (FASCAL) is the primary facility for calibration of spectral irradiance and spectral radiance at NIST and has been in continuous use since the early 1970s. Due to the increasing demands for s
Autor:
P. Y. Barnes, J. E. Proctor
Publikováno v:
Journal of Research of the National Institute of Standards and Technology
A new reflectometer-spectrophotometer has been designed and constructed using state-of-the-art technology to enhance optical properties of materials measurements over the ultraviolet, visible, and near-infrared (UV-Vis-NIR) wavelength range (200 nm t
Publikováno v:
Physical Review B.
Publikováno v:
Review of Scientific Instruments. 86:073102
We have developed a cryogenic amplifier for the measurement of small current signals (10 fA-100 nA) from cryogenic optical detectors. Typically operated with gain near 10(7) V/A, the amplifier performs well from DC to greater than 30 kHz and exhibits
Autor:
A. D. Hamilton, L. R. Hughey, Thomas R. O’Brian, R. P. Madden, J. E. Proctor, Mitchell L. Furst
Publikováno v:
Review of Scientific Instruments. 67:3345-3346
The Synchrotron Ultraviolet Radiation Facility (SURF II) at the National Institute of Standards and Technology, Gaithersburg, MD, USA, has served as a primary radiometric standard in the vacuum ultraviolet region since its conversion from a synchrotr
Publikováno v:
Fundamental and applied toxicology : official journal of the Society of Toxicology. 5(3)
Male and female Fischer-344 rats were exposed to methyl chloride by inhalation (0, 150, 475, or 1500 ppm, 6 hr/day, 5 days/week, 40 males and 80 females per group). The only treatment-related clinical signs were a 10 to 20% body weight gain depressio