Zobrazeno 1 - 10
of 35
pro vyhledávání: '"J. E. Gardener"'
Publikováno v:
Radiology. 192:253-259
To develop a system for three-dimensional (3D) ultrasonography (US) that readily interfaces with conventional equipment and to apply this system to fetal imaging.An acquisition system based on transputer technology records from the video output of st
Publikováno v:
The British Journal of Radiology. 66:588-591
We report our experience of 3-dimensional (3-D) reconstruction of ultrasound images of the uterine cavity. This is the first time that mapping of the contours of the uterine cavity with 3-D reconstruction has been achieved using standard clinical equ
Publikováno v:
Computer Assisted Radiology / Computergestützte Radiologie ISBN: 9783662008096
Carcinoma of the bile duct is a common problem with nearly half the patients presenting with obstructive jaundice from complex strictures within the bifurcating ducts of the hilum of the liver. It is extremely difficult to establish the full anatomic
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c3a39c3aa2e5b00bcedd83817d4c5950
https://doi.org/10.1007/978-3-662-00807-2_194
https://doi.org/10.1007/978-3-662-00807-2_194
Publikováno v:
Computer Assisted Radiology / Computergestützte Radiologie ISBN: 9783662008096
To date there has been relatively little work devoted to acquisition and display of 3D sets of ultrasound data. This is due both to technical problems of data acquisition, and theoretical and practical problems of how to render the complex informatio
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::c553eff55b5680f4267f97c1b13d1d45
https://doi.org/10.1007/978-3-662-00807-2_150
https://doi.org/10.1007/978-3-662-00807-2_150
Accurate haemodynamic assessment of mitral stenosis by hydraulic formulas requires measurement of the mean valve gradient and the cardiac output. The calculation is laborious, particularly in the presence of atrial fibrillation when averaged values o
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::82f02858d52ca7452666f26c9e3af0f7
https://europepmc.org/articles/PMC1224819/
https://europepmc.org/articles/PMC1224819/
Autor:
Haberski, Adam1 (AUTHOR) ahaberski@gmail.com, Caterino, Michael S.1 (AUTHOR)
Publikováno v:
ZooKeys. 2024, Issue 1198, p193-277. 85p.
Autor:
J. E. Gardener
Publikováno v:
Journal of Medical Engineering & Technology. 14:115-115
Publikováno v:
Heart. 62:102-111
Phase and amplitude analysis was applied to intravenous digital left ventriculograms to avoid the artefacts associated with image subtraction. Eight controls and 40 patients with known coronary artery disease underwent digital left ventriculography b
Publikováno v:
European Heart Journal. 8:137-141
Autor:
E Harting, J E Gardener
Publikováno v:
Journal of Physics E: Scientific Instruments. 5:712-714
A neutral particle detector is described which consists of a set of thermocouple elements evaporated on to a thin mica disc supported at its edge. This design provides a high sensitivity over a large area whilst still having a reasonable short time c