Zobrazeno 1 - 10
of 48
pro vyhledávání: '"J. B. Finlay"'
Publikováno v:
Experimental Mechanics. 35:166-173
Due to its ease of application, Fuji prescale pressure-sensitive film is currently one of the more popular methods, within the biomechanics community, for assessing contact areas and pressures within articulating joints—in addition to its use in in
Publikováno v:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 209:37-50
To determine whether dimensional scaling (relative to the human) is necessary for screwed pins used in externally applied fracture fixation studies on sheep, geometrical data were determined for six ovine tibiae. Each tibia was potted relative to a l
Publikováno v:
ResearcherID
SummaryThe purpose of this study was to examine the effect of pin design and drill/pin cooling on the biological response of bone in the near (entry) and far (exit) cortices of mature intact sheep tibiae. Two pins with markedly different characterist
Autor:
W R Hardie, J B Finlay
Publikováno v:
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 208:27-32
Cortical bone from the bovine femur has been studied to determine any changes in dimensions that might be caused by dehydration and subsequent rehydration of the samples. Nine control and ten embalmed axially oriented parallelepiped samples were prod
Publikováno v:
Medicine and science in sports and exercise. 27(9)
Two swims (1993 and 1994) are described which led to post-swim orthostatic intolerance and one episode of syncope in a 50/51-yr-old well-trained and experienced marathon swimmer. The swims of 33 km and 38 km took 12 h 30 s and 17 h 35 min, respective
Publikováno v:
Medical engineeringphysics. 16(6)
Fuji Prescale film is a pressure-sensitive medium which produces a characteristic pink stain on the application of pressure. Up to a saturation level, increases in pressure will produce a denser stain, thereby providing a method of determining pressu
Autor:
F L, Drijber, J B, Finlay
Publikováno v:
Journal of biomedical engineering. 14(6)
Slippage of the universal joints of external fixation devices is known to occur but its significance or incidence is often overlooked. In this study, controlled experiments were used to determine the relationship between joint slippage and the maximu
Autor:
J. B. Finlay
Publikováno v:
Strain Measurement in Biomechanics ISBN: 9789401050296
Strain measurements in orthopaedic biomechancis often involve bone with its characteristic anisotropic mechanical properties. Photoelastic coatings offer one mechanism for monitoring the full-field distribution of shear strains on the bone. These coa
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0d5e71a9499ca08be27d49b05987441e
https://doi.org/10.1007/978-94-011-2330-3_8
https://doi.org/10.1007/978-94-011-2330-3_8
Autor:
E. G. Little, J. B. Finlay
Publikováno v:
Strain Measurement in Biomechanics ISBN: 9789401050296
Strain measurements in biomechanics are a challenge, even with the established techniques of stain gauges, brittle lacquers, holography, thermography, photoelastic coatings and two-dimensional or three-dimensional photoelastic modelling; however, wit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::df845716c31ed2c5b58ac2632d3900b9
https://doi.org/10.1007/978-94-011-2330-3_1
https://doi.org/10.1007/978-94-011-2330-3_1
Autor:
F. L. I. P. Drijber, J. B. Finlay
Publikováno v:
Annals of biomedical engineering. 20(5)
Hoffmann half-frame external fixation device configurations often fail under minimal loads secondary to joint slippage. In these experiments improved universal joints that were developed in an earlier study were tested on Hoffmann half-frame assembli