Zobrazeno 1 - 10
of 14
pro vyhledávání: '"J. Allen Gammon"'
Autor:
Alcides Fernandes, J. Allen Gammon, R. Doyle Stulting, Randy J. Epstein, Margarete Tigges, John D. Wright
Publikováno v:
Ophthalmology. 93:1495-1501
Extended-wear contact lenses (EWCL) are being used increasingly for the correction of aphakia in infants, but there is a lack of data documenting their effects on the corneas of young children. Therefore, corneal studies were performed on infant monk
Publikováno v:
Ophthalmology. 91:1222-1230
Retrospectively studied were 91 patients, 14 years of age or less, who had 152 penetrating keratoplasties in 107 eyes, with an average follow-up of 30.1 months. Survival analysis showed the probability of obtaining a clear graft at one year to be 60
Publikováno v:
Behavior Research Methods, Instruments, & Computers. 20:11-17
Infant rhesus monkeys were fitted with extended-wear contact lenses (EWCLs) to correct surgically induced aphakia. The protocol that produced the most favorable experimental outcome, including good lens-wear compliance, involved: (1) custom-made EWCL
Autor:
Kerry L. Quinn, J. Allen Gammon
Publikováno v:
American Orthoptic Journal. 33:99-104
Publikováno v:
Ophthalmology. 95:1102-1106
Although hydrogel extended-wear contact lenses (EWCLs) have been used extensively in the correction of aphakia in neonates, little is known about the effects of these lenses on infant corneas. Recent studies have demonstrated that long-term contact l
Autor:
J. Allen Gammon
Publikováno v:
American Orthoptic Journal. 34:44-51
Autor:
J. Allen Gammon
Publikováno v:
Pediatrics In Review. 4:71-73
Many abnormalities of the visual system in infants and young children respond to treatment when instituted at an early age. Ocular abnormalities that require early recognition and therapy include congenital cataracts, congenital glaucoma, intraocular
Visual evoked potential pattern generation, recording, and data analysis with a single microcomputer
Publikováno v:
Electroencephalography and clinical neurophysiology. 56(6)
A single microcomputer is used to generate multiple sets of checkerboard patterns, simultaneously record EEG data for visual evoked potentials, and analyze the results by fast Fourier transform in very rapid sequence under operator control. This syst
Publikováno v:
Ophthalmology. 93(12)
The incidence, severity, and duration of ptosis after botulinum neurotoxin type A (BAT) injections into extraocular or orbicularis muscles were reviewed retrospectively. Even though lid droop frequently complicated botulinum toxin treatment in this s
Publikováno v:
Journal of pediatric ophthalmology and strabismus. 23(6)
Obstruction of the lacrimal drainage system is a common problem in pediatric ophthalmology. We describe a simple office test which allows the patency of the lacrimal drainage system to be visualized.