Zobrazeno 1 - 10
of 34
pro vyhledávání: '"J P, Le Normand"'
Publikováno v:
NEWCAS
A transmission line induced skew reduction system for shutter signals of a pixel array has been designed using TowerJazz CIS 0.18m technology. It is based on the use of multiple delay-locked loop in charge of close-to-close synchronization. The simul
Autor:
Daniel Mathiot, Chantal-Virginie Zint, Yann Hu, J.-P. Le Normand, Wilfried Uhring, Frédéric Morel
Publikováno v:
IEEE Sens. J.
IEEE Sens. J., 2006, 6, pp. 1200-1208
IEEE Sensors Journal
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2006, 6, pp.1200-1208. ⟨10.1109/JSEN.2006.881356⟩
IEEE Sens. J., 2006, 6, pp. 1200-1208
IEEE Sensors Journal
IEEE Sensors Journal, Institute of Electrical and Electronics Engineers, 2006, 6, pp.1200-1208. ⟨10.1109/JSEN.2006.881356⟩
High-speed cameras use the interesting performances of CMOS imagers that offer advantages in on-chip functionalities, system power reduction, cost, and miniaturization. The FAst MOS Imager (FAMOSI) project consists in reproducing the streak camera fu
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 52:1892-1897
Active pixel sensors (APS) technology offers performance competitive with charge-coupled device technology, and it offers advantages in on-chip functionality, system power reduction, cost, and miniaturization. In this paper, we present the design and
Autor:
C. Colledani, Marc Winter, D. Husson, Gilles Claus, Yann Hu, J. P. Le Normand, Renato Turchetta, W. Dulinski, B. Casadei, J.L. Riester, J.D. Berst, Ulrich Goerlach, Grzegorz Deptuch, S. Higueret
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2001, 458, pp.677-689
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2001, 458, pp.677-689
A novel Monolithic Active Pixel Sensor (MAPS) for charged particle tracking made in a standard CMOS technology is proposed. The sensor is a photodiode, which is readily available in a CMOS technology. The diode has a special structure, which allows t
Publikováno v:
3rd IEEE International Conference on Sensors (Sensors 2004)
Scopus-Elsevier
Scopus-Elsevier
Nowadays, imagers based on CMOS active pixel sensors (APS) have performances that are competitive with those based on charge-coupled devices (CCD). CMOS imagers offer advantages in on-chip functionalities, system power reduction, cost and miniaturiza
Publikováno v:
SPIE Proceedings.
CMOS active pixel sensors (APS) have performances competitive with charge-coupled device (CCD) technology, and offer advantages in on-chip functionality, system power reduction, cost and miniaturization. In this paper, we present characterization of
Publikováno v:
IFIP Advances in Information and Communication Technology ISBN: 9781475765304
VLSI-SOC
VLSI-SOC
In this paper, the results of the first temporal resolution imager CMOS for high-speed laser pulse characterisation are presented. This new imager can replace the conventional streak camera using a charge-coupled device (CCD) sensor for some applicat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a279c9e812c9d35e6f7837836608f0e9
https://doi.org/10.1007/978-0-387-35597-9_38
https://doi.org/10.1007/978-0-387-35597-9_38
Publikováno v:
Measurement Science and Technology. 21:115203
The conventional streak camera (CSC) is an optoelectronic instrument that captures the spatial distribution as a function of time of an ultra high-speed luminous phenomenon with picosecond temporal resolution and a typical spatial resolution of sever
Autor:
Langanay T, Y. Logeais, Alain Leguerrier, J. Boulvard, J. P. Le Normand, Rioux C, H. Le Coulis, Delambre Jf
Publikováno v:
European Heart Journal. 9:121-127
From 1971 to 1985, 355 patients over 70 years of age (mean age 73.7) underwent isolated aortic valve replacement, most of them for pure calcified stenosis (78.6%). Mechanical valves (group A) were used in 112 cases (109 Bjork-Shiley; 3 SJM) and biopr
Publikováno v:
Archives des maladies du coeur et des vaisseaux. 78(6)
The authors report a case of a 35 year old man with of congestive cardiac failure. Echocardiography showed diffuse hypokinetic wall motion with moderate parietal hypertrophy without dilatation. Post-mortem examination showed intramyocardial deposits