Zobrazeno 1 - 9
of 9
pro vyhledávání: '"J E Palethorpe"'
Publikováno v:
Physics in Medicine and Biology. 42:2383-2391
A metal oxide semiconductor field effect transistor (MOSFET), p-type semiconductor and a TLD can all be used for x-ray dosimetry, with each system having the common disadvantage of a response which is dependent upon the incident photon energy, partic
Publikováno v:
Radiation Protection Dosimetry. 67:41-46
The establishment and application is described of a number of standard IEC radiation qualities (IEC 1267: 1994-09) for the calibration of test instrumentation used in patient dose auditing in diagnostic radiology. Comparisons are drawn between two pr
Autor:
Denise E. Peach, Jerry C. Rosen, Fiona E. McNeill, Sandra J. Strosko, Michael J. Tobin, J E Palethorpe, Andrew C. Todd, David R. Chettle
Publikováno v:
Environmental Research. 57:117-132
Independent experiments have been performed at two centers, to evaluate the dosimetric properties of their respective 109Cd K X-ray fluorescence (XRF) bone lead measurement systems. Measurements were made of the dose to several points on the skin on
Publikováno v:
The British journal of radiology. 78(930)
LiF:Mg:Cu:P thermoluminescent dosemeters (TLD) can be used for the same X-ray dosimetry applications as LiF:Mg:Ti, with each type having the disadvantage of a response dependent on energy, particularly at low energies. Measurements were made of the r
Publikováno v:
Journal of radiological protection : official journal of the Society for Radiological Protection. 19(1)
The responses of several types of surface contamination monitor have been investigated for three typical working surfaces contaminated by three radionuclides commonly used in diagnostic or analytical biomedical applications. Of the three radionuclide
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 50(1)
Experiences of the Regional Radiation Physics and Protection Service (RRPPS) in performance assessment of diagnostic X-ray QA instrumentation and on-patient dosemeters are recounted. Issues relating to the provision of realistic and reproducible refe
Autor:
A D Lewis, David R. Chettle, P J Mountford, D.A. Bradley, D Mearman, Stuart Green, W D Morgan, J E Palethorpe
Publikováno v:
Physics in medicine and biology. 38(3)
A novel irradiation-detection geometry capable of enhancing sensitivity for the measurement of tibial lead content by K-shell x-ray fluorescence (XRF) is described. The high-count-rate system comprised a small-area high-specific-activity (0.147 GBq m
Autor:
Harry Roels, Robert Lauwerys, D.A. Bradley, Stuart Green, W D Morgan, David R. Chettle, P J Mountford, J E Palethorpe, David H. Mearman, J. Konings
Publikováno v:
Human Body Composition ISBN: 9781489912701
There has been a long history of in vivo bone lead measurements using the K-shell X-ray fluorescence technique (XRF) 1–3. This approach has found particular use for studies of integrated lead exposure in occupationally exposed groups and associated
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::943ecee7e17c4184720f76f9fe66872b
https://doi.org/10.1007/978-1-4899-1268-8_65
https://doi.org/10.1007/978-1-4899-1268-8_65
Autor:
S, Green, D A, Bradley, H A, Roels, P J, Mountford, W D, Morgan, D R, Chettle, J F, Konings, J E, Palethorpe, D H, Mearman, R R, Lauwerys
Publikováno v:
Basic life sciences. 60