Zobrazeno 1 - 9
of 9
pro vyhledávání: '"J C Male"'
Publikováno v:
Occupational and Environmental Medicine. 40:462-465
Pacemaker function was tested in two electricity substation workers exposed to high tension electric fields. High intensity electric fields induced reversion to the interference mode, producing in one case competitive rhythm and in the other inapprop
Publikováno v:
Occupational and Environmental Medicine. 42:75-84
The results of health questionnaire interviews with 390 electrical power transmission and distribution workers, together with long term estimates of their exposure to 50 Hz electric fields, and short term measurements of the actual exposure for 287 o
Publikováno v:
Journal of Physics E: Scientific Instruments. 1:373-378
Liquid semiconductors are considered for use as temperature measuring elements in nuclear reactors. Several possible compositions in the system As-S-Se-Te-Ge have been studied. They are liquid above about 300°C, have temperature coefficients of resi
Autor:
J. C. Male, P. J. Dean
Publikováno v:
Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences. 277:330-347
Luminescence excitation spectra in the quantum energy interval 5.0 to 7.5 eV (2400 to 1600 Å) have been obtained for some seventy natural diamonds of gem quality. Below 5.55 eV, structure is present which is directly related to certain components of
Autor:
J C Male
Publikováno v:
Proceedings of the Physical Society. 77:869-875
Luminescence excitation spectra have been obtained, at room temperature, for 13 natural diamonds comprising six of type I, three of type IIa, three of `intermediate' type and a single, semiconducting diamond. Excitation peaks, corresponding in detail
Autor:
J C Male
Publikováno v:
British Journal of Applied Physics. 18:1543-1549
A Hall effect measurement technique is described which overcomes some of the difficulties presented by materials combining a small Hall angle with a large temperature coefficient of conductivity. The major problem of `offset' voltage suppression is d
Publikováno v:
Pacing and clinical electrophysiology : PACE. 11(7)
The effects of injected 50 Hz alternating current on the function of cardiac pacemakers has been observed in 18 patients with implanted unipolar VVI units. Current, in the range 0-600 microA was applied via electrodes attached to the patients' upper
Autor:
J. C. Male, J. R. Prior
Publikováno v:
Nature. 186:1037-1038
DETAILED observations have been recently reported of radiation emission in germanium and silicon, which has been interpreted in terms of exciton recombination with emission and absorption of phonons1,2. In view of the similarities between these subst
Publikováno v:
British Journal of Applied Physics. 15:101-102
The inhomogeneous spatial distribution of the efficiency of excitation of visible luminescence by ultra-violet quanta, which are absorbed by intrinsic processes resulting in the production of excitons, has been measured for a semiconducting diamond.