Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Jérémie Pescatore"'
Publikováno v:
IEEE Transactions on Medical Imaging
IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2016, 35 (6), pp.1565-1574. ⟨10.1109/TMI.2016.2520092⟩
IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2016, 35 (6), pp.1565-1574. ⟨10.1109/TMI.2016.2520092⟩
In the past 20 years, a wide range of complex fluoroscopically guided procedures have shown considerable growth. Biologic effects of the exposure (radiation induced burn, cancer) lead to reduce the dose during the intervention, for the safety of pati
Publikováno v:
International Journal of Computer Assisted Radiology and Surgery. 3:79-83
Transcatheter chemoembolization of liver tumors is performed under X-ray fluoroscopic image guidance. This is a difficult procedure because the vessels of the liver are constantly moving due to respiration and they are not visible in the X-ray image
Publikováno v:
ICIP
We propose a temporal motion-compensated filter operating on dual-tree complex wavelet coefficients to denoise low-dose X-ray sequences. This filter allows for a great noise reduction while preserving moving objects and structures. We take advantage
Publikováno v:
SPIE Proceedings.
Hyperspectral imaging (HSI) is being evaluated as a pre-selection tool to categorize and localize populations of microbial colonies directly onto their culture medium, in order to facilitate the microbiology workflow downstream the incubation step. T
Publikováno v:
IEEE Transactions on Medical Imaging
IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2015, 34 (1), pp.137-147. ⟨10.1109/TMI.2014.2349034⟩
IEEE Transactions on Medical Imaging, Institute of Electrical and Electronics Engineers, 2015, 34 (1), pp.137-147. ⟨10.1109/TMI.2014.2349034⟩
International audience; —Image guided interventions have seen growing interest in recent years. The use of X-rays for the procedure impels limiting the dose over time. Image sequences obtained thereby exhibit high levels of noise and very low contr
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::84c3e5786bb2cf82b1f6bd94ca67acc6
https://hal.archives-ouvertes.fr/hal-01260393
https://hal.archives-ouvertes.fr/hal-01260393
Publikováno v:
Graphical Models. 67:260-284
This paper deals with topological analysis of sets of tetrahedra ("tetrahedral meshes" of three-dimensional objects). We introduce a definition of simple elements for any normal tetrahedral representation. Then we prove a local characterization of si
Autor:
Jérémie Pescatore, Razmig Kéchichian, Michel Desvignes, Jocelyn Chanussot, Carole Amiot, C. Girard
Publikováno v:
ICIP 2014-21st IEEE International Conference on Image Processing
ICIP 2014-21st IEEE International Conference on Image Processing, Oct 2014, Paris, France. pp.2659-2663, ⟨10.1109/ICIP.2014.7025538⟩
ICIP
ICIP 2014-21st IEEE International Conference on Image Processing, Oct 2014, Paris, France. pp.2659-2663, ⟨10.1109/ICIP.2014.7025538⟩
ICIP
International audience; We propose an image denoising method which takes curvelet domain inter-scale, inter-location and inter-orientation dependencies into account in a maximum a posteriori labeling of the curvelet coefficients of a noisy image. The
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::eec5622972698346ed075f779cedbbd8
https://hal.univ-grenoble-alpes.fr/hal-01128450
https://hal.univ-grenoble-alpes.fr/hal-01128450
Publikováno v:
IEEE Transactions on Biomedical Engineering. 48:1080-1087
A new method based on a multiresolution approach for solving the ill-posed problem of brain electrical activity reconstruction from electroencephaloram (EEG)/magnetoencephalogram (MEG) signals is proposed in a distributed source model. At each step o
Publikováno v:
Medical Imaging: Image Processing
X-ray exposure during image guided interventions can be important for the patient as well as for the medical staff. Therefore dose reduction is a major concern. Nevertheless, decreasing the dose per image affects significantly the image quality. As a
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 46:35-37