Рассматривается методика диагностического обследования экранированных токопроводов с воздушной изоляцией. Приводятся характерные пр
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::99ca35fd0919e15d061c33234542aaca
Autor:
Ahmadreza Eslami
Publikováno v:
International Journal of Electrical Power & Energy Systems. 96:238-252
Three-phase bus impedance matrix reveals some good potential in fault analysis in phase coordinates. In this paper, a comprehensive methodology is proposed to analyze a large variety of faults including short circuits in buses and lines, open circuit
Publikováno v:
IEEE Transactions on Industrial Electronics. 65:309-320
This paper proposes a new n-port hybrid dc circuit breaker for offshore multi-terminal HVDC grid application. The n-port dc circuit breaker can substitute n-1 hybrid dc circuit breakers at a dc bus with n-1 adjacent dc transmission lines. The system
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Kniha
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
IEEE Transactions on Power Electronics. 32:3007-3021
Under a short-circuit fault in low-voltage dc microgrid, solid-state circuit breaker (SSCB) assumes the responsibility of the quick and effective isolation of the faulted area, while its own safety and reliability depends on the overvoltage suppressi
Publikováno v:
Electric Power Systems Research. 142:341-350
Due to the supply reliability concerns or to supply remote loads in some distribution networks, the synchronous generators are used as auxiliary power sources. In Poland the generators are usually connected to the network of TN (earthed neutral point
Publikováno v:
IEEE Transactions on Components, Packaging and Manufacturing Technology. :1-9
As a part of the power system, the stability of the enclosed isolated-phase bus bar (EIPB) plays an important role in the working safety of the power system. Usually, the dynamic-thermal stability of EIPB is analyzed by the theoretical analysis or th
Publikováno v:
Journal of Power and Energy Engineering. :74-91
It has been recognized recently that when injecting renewable energy source power to a load bus which connected to a distributed feeder in a power grid system, a stability problem occurs particularly when having high fault duties that exceeding the c
Publikováno v:
IEEE Transactions on Power Electronics. 31:258-269
Single-phase inverters must include an energy storage device, typically a high-voltage bus capacitor, to match the inverter constant input power to its pulsating output power. Because of its increased cost, the size of this bus capacitor must be mini