Zobrazeno 1 - 10
of 4 158
pro vyhledávání: '"Isocenter"'
Publikováno v:
Precision Radiation Oncology, Vol 8, Iss 2, Pp 77-84 (2024)
Abstract Objective This study aimed to analyze the effect of different gantry angles on portal imaging in terms of isocenter shifts and their dosimetric impact on dose delivery. Methods Thirty patients with head and neck cancers were prospectively se
Externí odkaz:
https://doaj.org/article/425cfa2601534775be80181f602d4ac0
Autor:
Dante P. I. Capaldi, Lawrie B. Skinner, Daniel W. Pinkham, Sergei Zavgorodni, Olga Stafford, Maryam Shirmohammad, Jason E. Matney, Piotr Dubrowski, Paul De Jean, Elliot M. Grafil, Amy S. Yu
Publikováno v:
Frontiers in Oncology, Vol 14 (2024)
BackgroundBrain radiosurgery treatments require multiple quality-assurance (QA) procedures to ensure accurate and precise treatment delivery of ablative doses. As single-isocenter multitarget radiosurgery treatments become more popular for treating p
Externí odkaz:
https://doaj.org/article/f3b25a59ce584a6fa12607be76808456
Publikováno v:
Frontiers in Physics, Vol 12 (2024)
Medical accelerators have been widely used in tumor radiation therapy. Accurate isocenter coincidence between treatment beams and imaging systems is critical for image-guided radiation therapy (IGRT). We propose a method utilizing a phantom with mark
Externí odkaz:
https://doaj.org/article/e4d7a4a6c8a545439975a4726c3ef869
Publikováno v:
Iranian Journal of Medical Physics, Vol 20, Iss 5, Pp 290-297 (2023)
Introduction: This study quantifies the dosimetric impact of lateral and longitudinal positioning errors on left-sided breast cancer during 3D conformal radiation therapy, employing both mono isocenter (MIT) and double isocenter technique (DIT) irrad
Externí odkaz:
https://doaj.org/article/773034bb4e434a7c8fcf89a4955005e7
Autor:
Yoshiko Oshiro, Masashi Mizumoto, Yuichi Kato, Yukihiro Tsuchida, Koji Tsuboi, Takeji Sakae, Hideyuki Sakurai
Publikováno v:
Technical Innovations & Patient Support in Radiation Oncology, Vol 29, Iss , Pp 100235- (2024)
Purpose: To compare the dosimetric quality of automatic multiple brain metastases planning (MBM) with that of Cyberknife (CK) based on the clinical tumor condition, such as the tumor number, size, and location. Methods: 76 treatment plans for 46 pati
Externí odkaz:
https://doaj.org/article/20022b22948f46d2ad077faf97c5e9fa
Autor:
Takaaki Ito, Kazuki Kubo, Hajime Monzen, Yuya Yanagi, Kenji Nakamura, Yusuke Sakai, Yasumasa Nishimura
Publikováno v:
Journal of Medical Physics, Vol 48, Iss 4, Pp 365-372 (2023)
Purpose: The purpose of the study is to investigate the impact of large target offset distances on the dose distribution and gamma passing rate (GPR) in single-isocenter multiple-target stereotactic radiosurgery (SIMT SRS) using volumetric modulated
Externí odkaz:
https://doaj.org/article/774b3f7d7391432fb535aa2b8aff9287
Autor:
Eun Kyu Kim, Sung Yeop Kim, Jae Won Park, Jaehyeon Park, Ji Woon Yea, Yoon Young Jo, Se An Oh
Publikováno v:
Diagnostics, Vol 14, Iss 4, p 410 (2024)
HyperArc is a preferred technique for treating brain metastases, employing a single isocenter for multiple lesions. Geometrical isocentricity in the TrueBeam linear accelerator with HyperArc is crucial. We evaluated machine performance checks (MPCs)
Externí odkaz:
https://doaj.org/article/a32a8974dd054731834498ad123a5c3c
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Autor:
Michael Martin Eder, Michael Reiner, Christian Heinz, Sylvia Garny, Philipp Freislederer, Guillaume Landry, Maximilian Niyazi, Claus Belka, Marco Riboldi
Publikováno v:
Zeitschrift für Medizinische Physik, Vol 32, Iss 3, Pp 296-311 (2022)
Frameless single-isocenter non-coplanar stereotactic radiosurgery (SRS) for patients with multiple brain metastases is a treatment at high geometrical complexity. The goal of this study is to analyze the dosimetric impact of non-coplanar image guidan
Externí odkaz:
https://doaj.org/article/49d96ac0dcc749f8abc8856c86464beb