Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Iris Z. Wang"'
Publikováno v:
Medical Dosimetry. 46:219-228
In prone breast radiation, as the medial tangential beam usually passes through the immobilization board and couch, it is necessary to quantify the attenuation effect and the potential skin dose enhancement from these external structures. The prone b
Publikováno v:
Journal of Applied Clinical Medical Physics
Certain models of cone beam computed tomography (CBCT) image‐guided radiotherapy (IGRT) systems require manually placing the appropriate bowtie filter according to the relevant imaging protocol. Inadvertently using a wrong bowtie filter or no bowti
Publikováno v:
Journal of Applied Clinical Medical Physics
We report our technique for hemibody skin electron irradiation with a custom‐made plywood shield. The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six‐pair dual field (Stanford technique) at an ext
Publikováno v:
Radiology and Oncology, Vol 50, Iss 1, Pp 121-128 (2016)
Radiology and Oncology
Radiology and oncology (Ljubljana)
Radiology and Oncology
Radiology and oncology (Ljubljana)
Background This study is to report 1) the sensitivity of intensity modulated radiation therapy (IMRT) QA method for clinical volumetric modulated arc therapy (VMAT) plans with multi-leaf collimator (MLC) leaf errors that will not trigger MLC interloc
Publikováno v:
Journal of Applied Clinical Medical Physics
This study compares lung dose distributions for two common techniques of total body photon irradiation (TBI) at extended source‐to‐surface distance calculated with, and without, tissue density correction (TDC). Lung dose correction factors as a f
Publikováno v:
Medical physics. 39(6Part20)
Purpose: To demonstrate the dosimetric potential of volumetric modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non‐small cell lungcancer(NSCLC) with stereotactic body radiation therapy(SBRT).Methods:
Publikováno v:
Journal of Applied Clinical Medical Physics
Traditionally, total skin electron patients remove all clothing for treatment. It is generally assumed that this is best for the treatment of superficial skin lesions out of concern clothing may significantly perturb dose. We investigate the dosimetr
Publikováno v:
Journal of Applied Clinical Medical Physics
Purpose The aim of this study was to find an optimized configuration of collimator angle, couch angle, and starting tracking phase to improve the delivery performance in terms of MLC position errors, maximal MLC leaf speed, and total beam-on time of
Autor:
Daniel J. Bourgeois, J. Gomez, Todd L. Demmy, Harish K. Malhotra, Mark Hennon, Sai Yendamuri, L Kumaraswamy, Iris Z. Wang
Publikováno v:
Practical radiation oncology. 6(6)
Background By avoiding chest wall resection, iridium-192 (Ir-192) high-dose-rate (HDR) intraoperative brachytherapy (IOBT) and video-assisted thoracoscopic surgery (VATS) might improve outcomes for high-risk patients requiring surgical resection for
Publikováno v:
Medical Physics. 39:2956-2963
Purpose: Stereotactic body radiation therapy(SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses,treatments are typically protracted and there are more field