Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Irena Koniarová"'
Autor:
Dan Wichterle, Lucie Sediva, Lucie Necasova, Josef Kautzner, Irena Koniarová, Luděk Haman, Martin Doležel
Publikováno v:
Cor et Vasa. 63:518-522
odborneho stanoviska poskytuje ramcový přehled potencialnich poruch funkce kardiostimulatorů a kardioverterů-defibrilatorů v souvislosti s radioterapii a navrhuje metodický postup pro průběh celeho procesu radioterapie u pacientů s implantov
Autor:
Efi Koutsouveli, B. Petrovic, Ben J.M. Heijmen, Albert Lisbona, Erato Stylianou Markidou, Margaret Moore, Tomasz Piotrowski, Antonio López Medina, Irena Koniarová, Nuria Jornet, Catharine H. Clark, Raphaël Moeckli, Cristina Garibaldi, Marion Essers, Jenny Bertholet, Ad J.J. Maas
Publikováno v:
Physica Medica, 84, 65-71. Associazione Italiana di Fisica Medica
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname
PURPOSE: ESTRO-EFOMP intend to update the core curriculum (CC) for education and training of medical physicists in radiotherapy in line with the European Commission (EC) guidelines on Medical Physics Experts (MPE), the CanMEDS methodology and recent
Autor:
Petr Gallus, Irena Koniarová, G. Neue, Vaclav Vrba, Milan Semmler, Katerina Peterkova, Petr Průša, Ondrej Koncek, Denis Dudas
Publikováno v:
Physica Medica. 82:332-340
There are various different detectors, which can be used for radiotherapy measurements, and more are about to be adopted. Hybrid pixel detectors (HPD) have been originally developed for the high energy physics. However, over the last few years they a
Publikováno v:
Radiation Protection Dosimetry. 186:362-366
This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with elect
Autor:
Irena Koniarová, Lucie Nečasová, Lucie Šedivá, Luděk Haman, Dan Wichterle, Josef Kautzner, Martin Doležel
Publikováno v:
Klinicka onkologie. 34
Autor:
J. Winiecki, Eric Pace, A. Makridou, Csilla Pesznyák, Irena Koniarová, J. Isidoro, Ad J.J. Maas, Brenda Byrne, Eliseo Vano, Adriaan A. Lammertsma, Christoph Bert, Marion Essers, Heidi S. Rønde, Vojtech Mornstein, N. Colgan, Carmel J. Caruana, Violeta Karenauskaite
Publikováno v:
Caruana, C J, Karenauskaite, V, Mornstein, V, Vano, E, Pace, E, Lammertsma, A A, Maas, A J J, Bert, C, Byrne, B, Colgan, N, Essers, M, Isidoro, J, Koniarova, I, Makridou, A, Pesznyak, C, Rønde, H S & Winiecki, J 2021, ' A generic curriculum development model for the biomedical physics component of the educational and training programmes of the non-physics healthcare professions ', Physica medica, vol. 85, pp. 32-41 . https://doi.org/10.1016/j.ejmp.2021.04.015
Caruana, C J, Karenauskaite, V, Mornstein, V, Vano, E, Pace, E, Lammertsma, A A, Maas, A J J, Bert, C, Byrne, B, Colgan, N, Essers, M, Isidoro, J, Koniarova, I, Makridou, A, Pesznyak, C, Rønde, H S & Winiecki, J 2021, ' A generic curriculum development model for the biomedical physics component of the educational and training programmes of the non-physics healthcare professions ', Physica Medica, vol. 85, pp. 32-41 . https://doi.org/10.1016/j.ejmp.2021.04.015
Physica medica, 85, 32-41. Associazione Italiana di Fisica Medica
Caruana, C J, Karenauskaite, V, Mornstein, V, Vano, E, Pace, E, Lammertsma, A A, Maas, A J J, Bert, C, Byrne, B, Colgan, N, Essers, M, Isidoro, J, Koniarova, I, Makridou, A, Pesznyak, C, Rønde, H S & Winiecki, J 2021, ' A generic curriculum development model for the biomedical physics component of the educational and training programmes of the non-physics healthcare professions ', Physica Medica, vol. 85, pp. 32-41 . https://doi.org/10.1016/j.ejmp.2021.04.015
Physica medica, 85, 32-41. Associazione Italiana di Fisica Medica
The objective of the study was the construction of a generic curriculum development model for the use of biomedical physics (BMP) educators teaching the non-physics healthcare professions (HCP) in Europe. A comprehensive, qualitative cross-sectional
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::511652ee252bf45791ecf6c13ea6ad9f
https://research.vumc.nl/en/publications/3d266ef4-ff14-4c54-9f9f-d2ba916b0718
https://research.vumc.nl/en/publications/3d266ef4-ff14-4c54-9f9f-d2ba916b0718
Autor:
L.P. Kaplan, Diego Jurado-Bruggeman, Marco Fusella, R. Canters, Victor Hernandez, Christian Rønn Hansen, Anna Bäck, Irena Koniarová, J. Götstedt, Nuria Jornet, Nobutaka Mukumoto, Lorenzo Placidi, Ana Vaniqui, Tomasz Piotrowski, L. Widesott
Publikováno v:
RADIOTHERAPY AND ONCOLOGY
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname
Radiotherapy and Oncology, 153, 26-33. Elsevier Ireland Ltd
Hernandez, V, Hansen, C R, Widesott, L, Bäck, A, Canters, R, Fusella, M, Götstedt, J, Jurado-Bruggeman, D, Mukumoto, N, Kaplan, L P, Koniarová, I, Piotrowski, T, Placidi, L, Vaniqui, A & Jornet, N 2020, ' What is plan quality in radiotherapy? The importance of evaluating dose metrics, complexity, and robustness of treatment plans ', Radiotherapy and Oncology, vol. 153, pp. 26-33 . https://doi.org/10.1016/j.radonc.2020.09.038
r-IIB SANT PAU: Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
Institut dInvestigació Biomèdica Sant Pau (IIB Sant Pau)
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname
Radiotherapy and Oncology, 153, 26-33. Elsevier Ireland Ltd
Hernandez, V, Hansen, C R, Widesott, L, Bäck, A, Canters, R, Fusella, M, Götstedt, J, Jurado-Bruggeman, D, Mukumoto, N, Kaplan, L P, Koniarová, I, Piotrowski, T, Placidi, L, Vaniqui, A & Jornet, N 2020, ' What is plan quality in radiotherapy? The importance of evaluating dose metrics, complexity, and robustness of treatment plans ', Radiotherapy and Oncology, vol. 153, pp. 26-33 . https://doi.org/10.1016/j.radonc.2020.09.038
r-IIB SANT PAU: Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
Institut dInvestigació Biomèdica Sant Pau (IIB Sant Pau)
Plan evaluation is a key step in the radiotherapy treatment workflow. Central to this step is the assessment of treatment plan quality. Hence, it is important to agree on what we mean by plan quality and to be fully aware of which parameters it depen
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::07454bdab1cfb1b4b1897223b4f08b60
https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=1254
https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=1254
Publikováno v:
Physica Medica. 44:66-71
Purpose The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Materials and methods Correction factors following s
Publikováno v:
Radiation Physics and Chemistry. 140:365-369
The aim of this study was to compare dosimetry with Gafchromic EBT2 and EBT3 films to the ion chamber array PTW seven29 in terms of their performance in clinical IMRT plan verification. A methodology for film processing and calibration was developed.
Autor:
Ondřej Konček, Irena Koniarová
Publikováno v:
Radiation protection dosimetry. 186(2-3)
The Exradin W1 plastic scintillator (Standard Imaging) was examined for measurement suitability in high-energy photon beams, high-energy electron beams and tomotherapy in terms of dose to water for reference fields. For photon beams, pulse repetition