Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Institute of Bio-Sensing Technology"'
Publikováno v:
IEEE Transactions on Industrial Electronics. 67:2411-2421
Supercapacitors offer an attractive energy storage solution for lifetime “fit and forget” photovoltaic (PV) energy harvesting powered wireless sensor nodes for internet of things (IoT) applications. Whilst their low storage capacity is not an iss
Despite the growing evidence of improved patient outcomes and of a substantially reduced environmental impact of propofol-based total intravenous anesthesia when compared to volatile-based techniques, the vast majority of general anesthetics still us
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5505d5018a38af87737af2027ad0a483
Autor:
Ramesh Mudududdla, Mohd Abdullaha, Damilare Akintade, Bhabatosh Chaudhuri, Sandip B. Bharate, Asma Derf, Ibidapo S. Williams
Publikováno v:
ACS Omega
© 2018 American Chemical Society. The overexpression of α-synuclein (α-syn) and its aggregation is the hallmark of Parkinson's disease. The α-syn aggregation results in the formation of Lewy bodies that causes neuronal cell death. Therefore, the
Autor:
Anthony G. Pipe, Michael Fisher, Kerstin Eder, Dejanira Araiza-Illan, David Western, Clare Dixon, Matt Webster
Publikováno v:
Webster, M, Western, D, Araiza Illan, D, Dixon, C, Eder, K I, Fisher, M & Pipe, A G 2019, ' A Corroborative Approach to Verification and Validation of Human–Robot Teams ', International Journal of Robotics Research (IJRR) . https://doi.org/10.1177/0278364919883338
Webster, M, Western, D, Araiza-Illan, D, Dixon, C, Eder, K, Fisher, M & Pipe, A G 2020, ' A corroborative approach to verification and validation of human–robot teams ', The International Journal of Robotics Research, vol. 39, no. 1, pp. 73-99 . https://doi.org/10.1177/0278364919883338
International Journal of Robotics Research
Webster, M, Western, D, Araiza-Illan, D, Dixon, C, Eder, K, Fisher, M & Pipe, A G 2020, ' A corroborative approach to verification and validation of human–robot teams ', The International Journal of Robotics Research, vol. 39, no. 1, pp. 73-99 . https://doi.org/10.1177/0278364919883338
International Journal of Robotics Research
We present an approach for the verification and validation (V&V) of robot assistants in the context of human-robot interactions (HRI), to demonstrate their trustworthiness through corroborative evidence of their safety and functional correctness. Key
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2866a73dc53232a83cac6f9851f75669
https://research-information.bris.ac.uk/en/publications/317769ac-0fb3-43ee-8513-c793860f1665
https://research-information.bris.ac.uk/en/publications/317769ac-0fb3-43ee-8513-c793860f1665
Publikováno v:
Materials
Materials, Vol 12, Iss 7, p 1126 (2019)
Volume 12
Issue 7
Materials, Vol 12, Iss 7, p 1126 (2019)
Volume 12
Issue 7
In this study, biosensors based on zinc oxide&ndash
copper oxide composite nano-surfaces were prepared using a simple and inexpensive distributed colloidal technique. Combinations of mixed dispersions with volume ratios of 1:1, 1:2 and 2:1 ZnO:C
copper oxide composite nano-surfaces were prepared using a simple and inexpensive distributed colloidal technique. Combinations of mixed dispersions with volume ratios of 1:1, 1:2 and 2:1 ZnO:C
Publikováno v:
Sensing and Bio-Sensing Research, Vol 23, Iss, Pp-(2019)
In this paper we present a non-contact, impedance-based sensor system capable of characterizing the toxic response of cells to three different types of toxin. ECV304 cells were treated with 1 mM Hydrogen peroxide, 5% Dimethyl Sulfoxide, and 10 μg/ml
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a3a6f62d7071b39b2a2be6e4b9c9b360
Publikováno v:
Sensors and Actuators B: Chemical. 330:129264
Heated metal oxide sensors have been widely studied for their ability to give a reversible change in the electrical resistance following the interaction with a volatile compound. Another feature is their inherent cataluminescence (CTL) properties whe
Autor:
Sharma, Rajni, Williams, Ibidapo S, Linda, Gatchie, Sonawane, Vinay R., Chaudhuri, Bhabatosh, Bharate, Sandip B.
© 2018 Elsevier Ltd Expression of cytochrome P450-1A1 (CYP1A1) is suppressed under physiologic conditions but is induced (a) by polycyclic aromatic hydrocarbons (PAHs) which can be metabolized by CYP1A1 to carcinogens, and (b) in majority of breast
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=core_ac_uk__::b8e510e2263029be574b53ee8dfc79d2
https://uwe-repository.worktribe.com/file/855901/1/1-s2.0-S0968089618316663-main.pdf
https://uwe-repository.worktribe.com/file/855901/1/1-s2.0-S0968089618316663-main.pdf
Facile and inexpensive fabrication of zinc oxide based bio-surfaces for C-reactive protein detection
Publikováno v:
Scientific Reports
Scientific Reports, Vol 8, Iss 1, Pp 1-9 (2018)
Scientific Reports, Vol 8, Iss 1, Pp 1-9 (2018)
The paper reports a biosensor formed from antibody coated ZnO nano-crystals which has been prepared using a rapid and inexpensive fabrication method which utilises colloidal dispersion enhanced using sonication. This technique was used to prepare hig
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5d32fe0710f37a6a85edf2d5cf01bc5d
https://uwe-repository.worktribe.com/file/862678/1/Cao_et_al-2018-Scientific_Reports.pdf
https://uwe-repository.worktribe.com/file/862678/1/Cao_et_al-2018-Scientific_Reports.pdf
Copyright © 2018 Inderscience Enterprises Ltd. This paper analyses the effects of parasitic capacitances of unit capacitors on the accuracy and the noise performance of the DAC capacitor array in a SAR ADC, showing that thermal noise of the array de
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ba806894ea14fdbb3d9e3da1ba13e998
https://uwe-repository.worktribe.com/file/904155/1/parasitics_final.pdf
https://uwe-repository.worktribe.com/file/904155/1/parasitics_final.pdf